USNO Analysis Report for I20332 ($20NOV27XU) 
       This report is a contributed analysis report that does not correspond to 
       the database maintained by the IVS Data Centers for this session.  
   (Analyzed by Andrew Sargent, US Naval Observatory.
    Spoolfile source: interactive nuSolve analysis.) 

Problems: None. 

Number of observations rejected during correlation:    0 

Number of observations not usable by the software:     3 

    observation   1, KOKEE   :WETTZELL, 3C371   , 18:45:21, quality codes - S:9, X:0 
    observation   3, KOKEE   :WETTZELL, 0641+392, 18:51:07, quality codes - S:9, X:0 
    observation   4, KOKEE   :WETTZELL, 0716+714, 18:53:56, quality codes - S:9, X:9 

Number of observations rejected during analysis:       0 

Other comments: None. 

Parameterization: 
   5 parameters: 
     UT1 offset 
     atmosphere offset for:
         KOKEE WETTZELL
     clock offset (0), first order term (1), and/or second order term (2) for:
         WETTZELL (0,1)

Clock breaks: None

Session Statistics 

  Observations:       17 scheduled 
                      17 correlated (included in the database) 
                      14 recoverable (usable in Solve/nuSolve) 
                      14 used
  Session fit:        42.261 ps
  UT1 formal error:   14.39 microsec 

Source Performance 

                    Number of Observations

                Scheduled  Correlated*    Used    

  0613+570              2           2        2
  0641+392              1           1        0
  0716+714              2           2        1
  0749+540              1           1        1
  0805+410              1           1        1
  0955+476              1           1        1
  1418+546              3           3        3
  NRAO512               2           2        2
  1746+470              1           1        1
  1758+388              2           2        2
  3C371                 1           1        0
  ------------  ---------  ----------   ------
  Source Total         17          17       14

 * Correlated means included in the database. 
   Please note that the number of recoverable (usable) observations 
   cannot be broken down by source for Intensive solutions.