USNO Analysis Report for I20192 ($20JUL10XU) 
       This report is a contributed analysis report that does not correspond to 
       the database maintained by the IVS Data Centers for this session.  
   (Analyzed by Nicole Geiger, Naval Observatory.
    Spoolfile source: interactive nuSolve analysis.) 

Problems: None. 

Number of observations rejected during correlation:    0 

Number of observations not usable by the software:     5 

Number of observations rejected during analysis:       0 

Other comments: None. 

Parameterization: 
   5 parameters: 
     UT1 offset 
     atmosphere offset for:
         KOKEE WETTZELL
     clock offset (0), first order term (1), and/or second order term (2) for:
         KOKEE (0,1)

Clock breaks: None

Session Statistics 

  Observations:       18 scheduled 
                      18 correlated (included in the database) 
                      13 recoverable (usable in Solve/nuSolve) 
                      13 used
  Session fit:        24.230 ps
  UT1 formal error:    9.11 microsec 

Source Performance 

                    Number of Observations

                Scheduled  Correlated*    Used    

  0016+731              1           1        1
  0059+581              2           2        0
  0133+476              2           2        2
  0529+483              1           1        1
  0716+714              1           1        1
  0804+499              1           1        1
  0805+410              1           1        1
  OJ287                 1           1        1
  0955+476              1           1        1
  1015+359              1           1        1
  1803+784              1           1        1
  2209+236              2           2        1
  2229+695              1           1        1
  2319+317              1           1        0
  2356+385              1           1        0
  ------------  ---------  ----------   ------
  Source Total         18          18       13

 * Correlated means included in the database. 
   Please note that the number of recoverable (usable) observations 
   cannot be broken down by source for Intensive solutions.