USNO Analysis Report for I20085 ($20MAR25XU) 
       This report is a contributed analysis report that does not correspond to 
       the database maintained by the IVS Data Centers for this session.  
   (Analyzed by Nicole Geiger, Naval Observatory.
    Spoolfile source: interactive nuSolve analysis.) 

Problems: None. 

Number of observations rejected during correlation:    0 

Number of observations not usable by the software:     1 
	
	observation   12, KOKEE   :WETTZELL, NGC6251 , 19:10:47, quality code X-band: 0 S-band: 0

Number of observations rejected during analysis:       0 

Other comments: None. 

Parameterization: 
   5 parameters: 
     UT1 offset 
     atmosphere offset for:
         KOKEE WETTZELL
     clock offset (0), first order term (1), and/or second order term (2) for:
         KOKEE (0,1)

Clock breaks: None

Session Statistics 

  Observations:       17 scheduled 
                      17 correlated (included in the database) 
                      16 recoverable (usable in Solve/nuSolve) 
                      16 used
  Session fit:        60.855 ps
  UT1 formal error:   19.95 microsec 

Source Performance 

                    Number of Observations

                Scheduled  Correlated*    Used    

  0016+731              1           1        1
  0059+581              1           1        1
  0133+476              1           1        1
  0718+793              1           1        1
  1053+815              1           1        1
  1300+580              1           1        1
  NGC6251               1           1        0
  1636+473              3           3        3
  NRAO512               1           1        1
  1746+470              1           1        1
  1803+784              1           1        1
  3C371                 1           1        1
  2229+695              1           1        1
  2356+385              2           2        2
  ------------  ---------  ----------   ------
  Source Total         17          17       16

 * Correlated means included in the database. 
   Please note that the number of recoverable (usable) observations 
   cannot be broken down by source for Intensive solutions.