BKG Analysis Report for Q19238 (19AUG26XK)
       This report is a contributed analysis report that does not correspond to 
       the database maintained by the IVS Data Centers for this session. 
   (Analyzed by Anastasiia Girdiuk, Federal Agency for Cartography and Geodesy 
				    Bundesamt für Kartographie und Geodäsie (BKG)
    Spoolfile source: interactive nuSolve analysis.) 

Problems: None.

Number of observations rejected during correlation:    0

Number of observations not usable by the software:     7

    observation    4,          2000+472, ISHIOKA:WETTZELL, 07:01:32, quality codes - S:0, X:9
    observation    7,          2000+472, SESHAN25:WETTZELL, 07:01:32, quality codes - S:0, X:8
    observation   66,          1156+295, ISHIOKA:NYALES20, 07:18:26, quality codes - S:0, X:0
    observation   69,          1156+295, NYALES20:SESHAN25, 07:18:26, quality codes - S:0, X:0
    observation   70,          1156+295, NYALES20:WETTZELL, 07:18:26, quality codes - S:0, X:0
    observation  119,          2000+472, ISHIOKA:WETTZELL, 07:35:15, quality codes - S:0, X:9
    observation  122,          2000+472, SESHAN25:WETTZELL, 07:35:15, quality codes - S:0, X:9

Number of observations rejected during analysis:       6

    observation   62,  ISHIOKA:NYALES20, 0059+581, 07:15:18, which fits at -354.5 +/- 40.9 ps
    observation   63,  ISHIOKA:WETTZELL, 0059+581, 07:15:18, which fits at -359.4 +/- 41.1 ps
    observation  102,  ISHIOKA:NYALES20, 0642+449, 07:27:29, which fits at -935.3 +/- 70.2 ps
    observation  103,  ISHIOKA:SESHAN25, 0642+449, 07:27:29, which fits at -908.4 +/- 42.5 ps
    observation  104,  ISHIOKA:WETTZELL, 0642+449, 07:27:29, which fits at -884.9 +/- 63.3 ps
    observation  167,  ISHIOKA:WETTZELL, 1806+456, 07:46:04, which fits at -151.4 +/- 62.7 ps

Other comments: 
    The vgosDb BKG analysis output is available at
    ftp://ivs.bkg.bund.de/pub/vlbi/ivsdata/vgosdb_bkg/19AUG26XK.tgz

Parameterization: 
   14 parameters:
     UT1 offset
     atmosphere offset for:
         ISHIOKA  NYALES20 SESHAN25 WETTZELL
     clock offset (0), first order term (1), and/or second order term (2) for:
         ISHIOKA (0,1,2) NYALES20(0,1,2) SESHAN25 (0,1,2)

Clock breaks: None.

-----------------------------------------

Session Statistics 

  Observations:      372 scheduled
                     218 correlated (included in the database) 
                     211 recoverable (usable in Solve/nuSolve) 
                     205 used 
  Session fit:        41.268 ps
  UT1 formal error:    4.560 microsec

-----------------------------------------


Source Performance 

                    Number of Observations

             Scheduled(*)  Correlated*    Used    


  0016+731             20          12       12
  0059+581             12           6        4
  0613+570              3           1        1
  0642+449             10           6        3
  0716+714             10           6        6
  0814+425             10           6        6
  0827+243              6           3        3
  0955+476             20          12       12
  1030+415             20          12       12
  1039+811             20          12       12
  1040+244             16           9        9
  1053+704             10           6        6
  1128+385             10           6        6
  1144+402             10           6        6
  1156+295             20          12        9
  1219+044              6           3        3
  1726+455             20          12       12
  1803+784             20          12       12
  1806+456             10           6        5
  1842+681             10           6        6
  1849+670             20          12       12
  2000+472             20          12        8
  2229+695             20          12       12
  2309+454              9           4        4
     3C371             20          12       12
     3C418             20          12       12
  ------------  ---------  ----------   ------
  Source Total        372         218      205

 *  Correlated means included in the database.
(*) All possible observations on scheduled network.
   Please note that the number of recoverable (usable) observations
   cannot be broken down by source for Intensive solutions.