USNO Analysis Report for Q19048 ($19FEB17XK) 
       This report is a contributed analysis report that does not correspond to 
       the database maintained by the IVS Data Centers for this session.  
   (Analyzed by Christopher Dieck, US Naval Observatory.
    Spoolfile source: interactive nuSolve analysis.) 

Problems: None. 

Number of observations rejected during correlation:    0 

Number of observations not usable by the software:     0 

Number of observations rejected during analysis:       3 

    observation  6, ISHIOKA :WETTZELL, 0016+731, 07:39:24, which fits at -3655.0 +/- 55.0 ps 
    observation 15, ISHIOKA :WETTZELL, 0016+731, 07:58:09, which fits at  -181.8 +/- 53.8 ps 
    observation 27, ISHIOKA :WETTZELL, 0016+731, 08:23:42, which fits at -3426.0 +/- 61.0 ps 

Other comments: None. 

Parameterization: 
   5 parameters: 
     UT1 offset 
     atmosphere offset for:
         ISHIOKA WETTZELL
     clock offset (0), first order term (1), and/or second order term (2) for:
         WETTZELL (0,1)

Clock breaks: None

Session Statistics 

  Observations:       29 scheduled 
                      29 correlated (included in the database) 
                      29 recoverable (usable in Solve/nuSolve) 
                      26 used
  Session fit:        39.325 ps
  UT1 formal error:   14.31 microsec 

Source Performance 

                    Number of Observations

                Scheduled  Correlated*    Used    

  0059+581              4           4        4
  0133+476              4           4        4
  1300+580              4           4        4
  1803+784              1           1        1
  3C371                 4           4        4
  3C418                 1           1        1
  2000+472              3           3        3
  0716+714              1           1        1
  1053+704              4           4        4
  0016+731              3           3        0
  ------------  ---------  ----------   ------
  Source Total         29          29       26

 * Correlated means included in the database. 
   Please note that the number of recoverable (usable) observations 
   cannot be broken down by source for Intensive solutions.