USNO Analysis Report for I19205 ($19JUL24XU) 
       This report is a contributed analysis report that does not correspond to 
       the database maintained by the IVS Data Centers for this session.  
   (Analyzed by Christopher Dieck, US Naval Observatory.
    Spoolfile source: interactive nuSolve analysis.) 

Problems: None. 

Number of observations rejected during correlation:    0 

Number of observations not usable by the software:    13 

    observation   3, ISHIOKA :WETTZELL, 1751+288, 18:32:28, quality codes - S:0, X:0 
    observation   5, ISHIOKA :WETTZELL, 0642+449, 18:34:45, quality codes - S:9, X:0 
    observation  11, ISHIOKA :WETTZELL, 1751+288, 18:42:13, quality codes - S:0, X:9 
    observation  14, ISHIOKA :WETTZELL, 0642+449, 18:45:53, quality codes - S:9, X:0 
    observation  23, ISHIOKA :WETTZELL, 0642+449, 18:55:23, quality codes - S:9, X:0 
    observation  26, ISHIOKA :WETTZELL, 1751+288, 18:59:04, quality codes - S:0, X:9 
    observation  31, ISHIOKA :WETTZELL, 0642+449, 19:04:28, quality codes - S:9, X:0 
    observation  33, ISHIOKA :WETTZELL, 1751+288, 19:06:45, quality codes - S:0, X:9 
    observation  38, ISHIOKA :WETTZELL, 0642+449, 19:12:09, quality codes - S:9, X:0 
    observation  45, ISHIOKA :WETTZELL, 0642+449, 19:19:53, quality codes - S:9, X:0 
    observation  47, ISHIOKA :WETTZELL, 1751+288, 19:22:12, quality codes - S:0, X:9 
    observation  50, ISHIOKA :WETTZELL, 0016+731, 19:25:26, quality codes - S:0, X:9 
    observation  52, ISHIOKA :WETTZELL, 0642+449, 19:27:37, quality codes - S:9, X:0 

Number of observations rejected during analysis:       2 

    observation  13, ISHIOKA :WETTZELL, NRAO512 , 18:44:15, which fits at -283.3 +/- 67.9 ps 
    observation  24, ISHIOKA :WETTZELL, NRAO512 , 18:57:03, which fits at -827.9 +/- 72.7 ps 

Other comments: Preliminary solution; the data for SVETLOE have not arrived yet. 

Parameterization: 
   5 parameters: 
     UT1 offset 
     atmosphere offset for:
         ISHIOKA WETTZELL
     clock offset (0), first order term (1), and/or second order term (2) for:
         WETTZELL (0,1)

Clock breaks: None

Session Statistics 

  Observations:       87 scheduled (from all stations---includes SVETLOE)
                      53 scheduled (from available stations---does not include
                                    SVETLOE)
                      53 correlated (included in the database) 
                      40 recoverable (usable in Solve/nuSolve) 
                      38 used
  Session fit:        64.604 ps
  UT1 formal error:   30.05 microsec 

Source Performance 

                    Number of Observations

                Scheduled  Correlated*    Used    

  0016+731             11           7        6
  0059+581             15           7        7
  0642+449              7           7        0
  NRAO512               5           3        1
  1726+455             14           8        8
  1751+288             11           7        2
  1803+784             11           7        7
  3C418                13           7        7
  ------------  ---------  ----------   ------
  Source Total         87          53       38

 * Correlated means included in the database. 
   Please note that the number of recoverable (usable) observations 
   cannot be broken down by source for Intensive solutions.