Starting generation of Calibration File 
FS version = 0009.0011.0019 
time_zero = 5245200 
Found #174 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. 
Found #154 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. 
Found #78 errors of type = ERROR ch   -4 Device v1 timed-out on response from MATCN 
Found #78 errors of type = ERROR ch   -4 Device v3 timed-out on response from MATCN 
Found #77 errors of type = ERROR ch   -4 Device v2 timed-out on response from MATCN 
Found #76 errors of type = ERROR ch   -4 Device v8 timed-out on response from MATCN 
Found #76 errors of type = ERROR ch   -4 Device v4 timed-out on response from MATCN 
Found #76 errors of type = ERROR ch   -4 Device v7 timed-out on response from MATCN 
Found #76 errors of type = ERROR ch   -4 Device v5 timed-out on response from MATCN 
Found #76 errors of type = ERROR ch   -4 Device v9 timed-out on response from MATCN 
Found #76 errors of type = ERROR ch   -4 Device v6 timed-out on response from MATCN 
Found #59 errors of type = ERROR st -504 Az power supply failure
 
Found #56 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. 
Found #22 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. 
Found #20 errors of type = ERROR an -103 Pointing computer tracking errors are too large. 
Found #20 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. 
Found #20 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. 
Found #20 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! 
Found #18 errors of type = ERROR ma   -4 Device i3 timed-out on response. 
Found #18 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. 
Found #18 errors of type = ERROR ma   -4 Device if timed-out on response. 
Found #17 errors of type = ERROR st  -14 Antenna stuck.
 
Found #14 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. 
Found #14 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. 
Found #14 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. 
Found #14 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. 
Found #14 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. 
Found #14 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. 
Found #14 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. 
Found #14 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. 
Found #14 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. 
Found #14 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. 
Found #6 errors of type = ERROR fl   -1 Previous source in this schedule not reached before new source was commanded 
Found #4 errors of type = ERROR ma   -4 Device vc timed-out on response. 
Found #4 errors of type = ERROR ma   -4 Device vd timed-out on response. 
Found #4 errors of type = ERROR ma   -4 Device va timed-out on response. 
Found #4 errors of type = ERROR ma   -4 Device v9 timed-out on response. 
Found #4 errors of type = ERROR ma   -4 Device v6 timed-out on response. 
Found #4 errors of type = ERROR ma   -4 Device ve timed-out on response. 
Found #4 errors of type = ERROR ma   -4 Device vb timed-out on response. 
Found #4 errors of type = ERROR ma   -4 Device v7 timed-out on response. 
Found #4 errors of type = ERROR ma   -4 Device v8 timed-out on response. 
Found #3 errors of type = ERROR ma   -4 Device v5 timed-out on response. 
Found #2 errors of type = ERROR ma   -4 Device v4 timed-out on response. 
Found #2 errors of type = ERROR sp   -4 Unrecognized name (not a function or procedure). 
Found #2 errors of type = ERROR ma   -4 Device v3 timed-out on response. 
Found #2 errors of type = ERROR ma   -4 Device v2 timed-out on response. 
Found #2 errors of type = ERROR an   -7 Antenna communications restored. 
Found #2 errors of type = ERROR ma   -4 Device v1 timed-out on response. 
Found #1 errors of type = ERROR ch -365 IF3 switch 2 setting does not check with request. 
Found #1 errors of type = ERROR 5h -302 background Mark 5 error(s) detected - see below 
Found these BBCs: vc01 vc05 vc09
NBBC: 3
Found these RX parameters: 02(LO) 03(DCAL) 05(INLET)
RX1 min= 47.97 max= 55.59
RX2 min= 38.45 max= 52.26
RX3 min= 30.35 max= 39.88
Plotting 3 Tsys channels: 01 05 09
Tsys values are: 1 2 3 etc
NTSYS: 3
in match_chan ft1= r4831ft.log.tsy1.ntup nt1= 7 st1= 1d tt= 1
set scale tsys1 [2] min max 130.5 305
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 142 ymax 305 
in match_chan ft1= r4831ft.log.tsy1.ntup nt1= 19 st1= 5u tt= 1
set scale tsys1 [2] min max 130.5 305
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 143.7 ymax 305 
in match_chan ft1= r4831ft.log.tsy1.ntup nt1= 12 st1= 9u tt= 1
set scale tsys1 [2] min max 130.5 305
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 107.5 ymax 305