IVS Analysis Report for Q18106 ($18APR16XK) 
       This report is the official IVS analysis report that corresponds to 
       the database maintained by the IVS Data Centers for this session.  
   (Analyzed by Karen Baver, Goddard Space Flight Center VLBI Analysis Center.
    Spoolfile source: interactive solve/nuSolve analysis.) 

Problems: None. 

Number of observations rejected during correlation:    4 

  The following observations were not correlated in X-band or S-band:

    observation at 07:00:00 by ISHIOKA -SESHAN25 of 1849+670
    observation at 07:00:00 by NYALES20-SESHAN25 of 1849+670
    observation at 07:00:00 by SESHAN25-WETTZELL of 1849+670

  The following observation was not correlated in X-band:

    observation at 07:31:13 by NYALES20-SESHAN25 of 0800+618

Number of observations not usable by the software:     1 

    observation    5, ISHIOKA :NYALES20, 0229+131, 07:05:38, quality code X-band: 0 S-band: 9 

Number of observations rejected during analysis:       1 

    observation  132, SESHAN25:WETTZELL, 1418+546, 07:55:04, which fits at      171.4 +/-      49.0 ps 

Other comments: 

  The correlator provided the following station notes:

    +STATION_NOTES

       ISHIOKA  (Is/Q): One non-detection in X-band on Is-Ny baseline.

       NYALES20 (Ny/N): One non-detection in X-band on Is-Ny baseline.

       SESHAN25 (Sh/C): Low fringe amplitude in channel XR8L leading to several
                        G codes; channel removed from fringe fitting.

       WETTZELL (Wz/V): Ok.

Parameterization: 
   14 parameters: 
     UT1 offset 
     atmosphere offset for:
         ISHIOKA NYALES20 SESHAN25 WETTZELL
     clock offset, first order term, and second order term for:
         NYALES20 WETTZELL

Clock breaks: None.

Session Statistics 

  Observations:      144 scheduled 
                     140 correlated (included in the database) 
                     139 recoverable (usable in Solve/nuSolve) 
                     138 used
  Session fit:        40.635 ps
  UT1 formal error:    6.16 microsec 

Source Performance 

                    Number of Observations

                Scheduled  Correlated*    Used    

  0059+581              6           6        6
  0133+476              6           6        6
  0229+131              6           6        5
  0552+398              6           6        6
  0718+793              6           6        6
  0955+476              6           6        6
  1300+580              6           6        6
  1418+546              6           6        5
  0800+618              6           5        5
  0019+058              6           6        6
  0215+015             12          12       12
  0307+380              6           6        6
  0415+398              6           6        6
  0529+483              6           6        6
  0716+714              6           6        6
  2309+454             12          12       12
  0016+731              6           6        6
  0017+200             12          12       12
  0202+319              6           6        6
  0642+449              6           6        6
  1849+670              6           3        3
  ------------  ---------  ----------   ------
  Source Total        144         140      138

 * Correlated means included in the database. 
   Please note that the number of recoverable (usable) observations 