USNO Analysis Report for I18306 ($18NOV02XU) 
       This report is a contributed analysis report that does not correspond to 
       the database maintained by the IVS Data Centers for this session.  
   (Analyzed by Christopher Dieck, US Naval Observatory.
    Spoolfile source: interactive nuSolve analysis.) 

Problems: None. 

Number of observations rejected during correlation:    0 

Number of observations not usable by the software:     5

    observation  2, NRAO512 , 18:34:10, quality codes - S:9, X:0
    observation  5, 1504+377, 18:45:25, quality codes - S:9, X:0
    observation 11, 1504+377, 19:06:47, quality codes - S:9, X:0
    observation 13, NRAO512 , 19:14:44, quality codes - S:9, X:0
    observation 15, 1504+377, 19:22:40, quality codes - S:9, X:0

Number of observations rejected during analysis:       0 

Other comments: None. 

Parameterization: 
   5 parameters: 
     UT1 offset 
     atmosphere offset for:
         KOKEE WETTZELL
     clock offset (0), first order term (1), and/or second order term (2) for:
         WETTZELL (0,1)

Clock breaks: None

Session Statistics 

  Observations:       17 scheduled 
                      17 correlated (included in the database) 
                      12 recoverable (usable in Solve/nuSolve) 
                      12 used
  Session fit:        36.393 ps
  UT1 formal error:   13.24 microsec 

Source Performance 

                    Number of Observations

                Scheduled  Correlated*    Used    

  0529+483              3           3        3
  0613+570              1           1        1
  0716+714              1           1        1
  0749+540              1           1        1
  1053+704              1           1        1
  1504+377              3           3        0
  NRAO512               2           2        0
  1639+230              2           2        2
  1803+784              2           2        2
  1849+670              1           1        1
  ------------  ---------  ----------   ------
  Source Total         17          17       12

 * Correlated means included in the database. 
   Please note that the number of recoverable (usable) observations 
   cannot be broken down by source for Intensive solutions.