USNO Analysis Report for I18303 ($18OCT30XU) 
       This report is a contributed analysis report that does not correspond to 
       the database maintained by the IVS Data Centers for this session.  
   (Analyzed by Christopher Dieck, US Naval Observatory.
    Spoolfile source: interactive nuSolve analysis.) 

Problems: None. 

Number of observations rejected during correlation:    0 

Number of observations not usable by the software:     3

    observation  8, NGC6251 , 18:55:50, quality codes - S:0, X:0
    observation  9, 1300+580, 18:59:49, quality codes - S:9, X:0
    observation 13, 1300+580, 19:15:53, quality codes - S:9, X:0 

Number of observations rejected during analysis:       0 

Other comments: None. 

Parameterization: 
   5 parameters: 
     UT1 offset 
     atmosphere offset for:
         KOKEE WETTZELL
     clock offset (0), first order term (1), and/or second order term (2) for:
         WETTZELL (0,1)

Clock breaks: None

Session Statistics 

  Observations:       16 scheduled 
                      16 correlated (included in the database) 
                      13 recoverable (usable in Solve/nuSolve) 
                      13 used
  Session fit:        15.705 ps
  UT1 formal error:    5.88 microsec 

Source Performance 

                    Number of Observations

                Scheduled  Correlated*    Used    

  0529+483              1           1        1
  0552+398              1           1        1
  0716+714              1           1        1
  0738+491              1           1        1
  1300+580              2           2        0
  1418+546              1           1        1
  NGC6251               1           1        0
  1636+473              2           2        2
  NRAO512               2           2        2
  1639+230              2           2        2
  DA426                 1           1        1
  3C371                 1           1        1
  ------------  ---------  ----------   ------
  Source Total         16          16       13

 * Correlated means included in the database. 
   Please note that the number of recoverable (usable) observations 
   cannot be broken down by source for Intensive solutions.