Starting generation of Calibration File FS version = 0009.0010.0003 time_zero = 8960400 Found #159 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #159 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #159 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #159 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #159 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #159 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #106 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #103 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #82 errors of type = ERROR ma -4 Device ve timed-out on response. Found #82 errors of type = ERROR ma -4 Device vc timed-out on response. Found #82 errors of type = ERROR ma -4 Device vd timed-out on response. Found #69 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #59 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #48 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #42 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #41 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #41 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #8 errors of type = ERROR an -102 Pointing computer command angles are incorrect. Found #4 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #2 errors of type = ERROR st -102 Pointing mode should be RADc but is AzEl Found #2 errors of type = ERROR ST -154 Getting Status Data from antenna: time-out on response. Found #2 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #1 errors of type = ERROR m5 -900 Can't XLRRead() Found #1 errors of type = ERROR qi -302 Last commanded IFD attenuations used as default please modify command. Found #1 errors of type = ERROR m5 -904 MARK5 return code 4: error encountered (during attempt to execute) Found these BBCs: vc03 vc07 vc11 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 03 07 11 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= t2068sm.log.tsy1.ntup nt1= 9 st1= 3u tt= 1 set scale tsys1 [2] min max 0.0 34.0 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 39 in match_chan ft1= t2068sm.log.tsy1.ntup nt1= 13 st1= 7u tt= 1 set scale tsys1 [2] min max 0.0 34.0 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 300 ymax 305 in match_chan ft1= t2068sm.log.tsy1.ntup nt1= 18 st1= bu tt= 1 set scale tsys1 [2] min max 0.0 34.0 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305