Starting generation of Calibration File FS version = 0009.0010.0004 time_zero = 2394000 Found #17 errors of type = ERROR st -903 The Receiver 20K stage is hotter than 30K. Found #15 errors of type = ERROR st -7 Antenna off-source! Found #5 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #3 errors of type = ERROR ch -308 v5 total power integrator overflow Found #2 errors of type = ERROR st -4 Interface not set to remote. Found #2 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #2 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #2 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #1 errors of type = ERROR m5 -900 Check formatter serial number even Found #1 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #1 errors of type = ERROR ch -308 vb total power integrator overflow Found #1 errors of type = ERROR ch -308 va total power integrator overflow Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR st -6 Antenna control restored. Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found these BBCs: NBBC: 0 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 0 Tsys channels: Tsys values are: 1 2 3 etc NTSYS: 0