Starting generation of Calibration File 
FS version = 0009.0010.0004 
time_zero = 13374000 
Found #133 errors of type = ERROR ch -317 Total power integrator overflow on IF2 
Found #24 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. 
Found #1 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. 
Found #1 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. 
Found #1 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. 
Found #1 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. 
Found #1 errors of type = ERROR ch -316 Total power integrator overflow on IF1 
Found #1 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. 
Found #1 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. 
Found #1 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. 
Found #1 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. 
Found #1 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. 
Found #1 errors of type = ERROR ch -308 v3 total power integrator overflow 
Found #1 errors of type = ERROR m5 -900 Check formatter serial number even 
Found #1 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. 
Found #1 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. 
Found #1 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. 
Found #1 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. 
Found #1 errors of type = ERROR ch -370 Total power integrator overflow on IF3 
Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request 
Found these BBCs: vc02 vc06 vc11
NBBC: 3
Found these  parameters:   
RX1 min= 100000 max= -1
RX2 min= 100000 max= -1
RX3 min= 100000 max= -1
Plotting 3 Tsys channels: 02 06 11
Tsys values are: 1 2 3 etc
NTSYS: 3
in match_chan ft1= r4433wz.log.tsy1.ntup nt1= 8 st1= 2u tt= 1
set scale tsys1 [2] min max 32.7 305
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 30.3 ymax 305 
in match_chan ft1= r4433wz.log.tsy1.ntup nt1= 20 st1= 6u tt= 1
set scale tsys1 [2] min max 32.7 305
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 19.8 ymax 305 
in match_chan ft1= r4433wz.log.tsy1.ntup nt1= 14 st1= bu tt= 1
set scale tsys1 [2] min max 32.7 305
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 55.2 ymax 305