Starting generation of Calibration File FS version = 0009.0010.0004 time_zero = 8344800 Found #45 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #45 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #38 errors of type = ERROR st -2 Antenna timed out. Found #36 errors of type = ERROR st -4 Interface not set to remote. Found #28 errors of type = ERROR st -7 Antenna off-source! Found #13 errors of type = ERROR an -7 Antenna communications restored. Found #6 errors of type = ERROR st -901 Receiver LO is unlocked. Found #4 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #4 errors of type = ERROR an -2 Time-out while waiting for a response Found #3 errors of type = ERROR st -6 Antenna control restored. Found #2 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR ch -308 v9 total power integrator overflow Found #1 errors of type = ERROR bo -312 Error already "off" for TNX. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 1u. Found #1 errors of type = ERROR bo -105 Error opening schedule file FMP FFF Found #1 errors of type = ERROR ch -308 v5 total power integrator overflow Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector i3. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector i3. Found #1 errors of type = ERROR fp -30 ANTCN failed too many times Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector i1. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR ch -308 vb total power integrator overflow Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 2u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector i1. Found #1 errors of type = ERROR m5 -900 Check formatter serial number even Found #1 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 1u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 2u. Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these SK parameters: 00(BXFNT) 02(LO_TMP) 03(DCAL_T) RX1 min= 20.80 max= 22.80 RX2 min= 47.20 max= 47.50 RX3 min= 33.20 max= 34.20 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r1425ny.log.tsy1.ntup nt1= 7 st1= 1u tt= 1 set scale tsys1 [2] min max 54.2 74.3 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 73.1 in match_chan ft1= r1425ny.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 54.2 74.3 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 47 ymax 76.7 in match_chan ft1= r1425ny.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 54.2 74.3 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 52.4 ymax 117.9