Starting generation of Calibration File FS version = 0009.0010.0004 time_zero = 7056000 Found #3107 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #332 errors of type = ERROR ch -308 ve total power integrator overflow Found #309 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #305 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #188 errors of type = ERROR ch -308 v9 total power integrator overflow Found #119 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #80 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #32 errors of type = ERROR ch -302 v1 frequency does not check with requested value Found #31 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #16 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #13 errors of type = ERROR ch -308 va total power integrator overflow Found #3 errors of type = ERROR mc -22 MCB device is dev null MCB devices inaccessible. Found #3 errors of type = ERROR ch -308 vb total power integrator overflow Found #3 errors of type = ERROR ch -4 Device v2 timed-out on response from MATCN Found #2 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #1 errors of type = ERROR ch -304 v2 TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -306 v2 LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -309 v2 alarm is on Found #1 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #1 errors of type = ERROR ch -309 vb alarm is on Found #1 errors of type = ERROR ch -305 v2 USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -307 v2 unlock indicator is on Found #1 errors of type = ERROR ch -302 v2 frequency does not check with requested value Found #1 errors of type = ERROR ch -303 v2 bandwidth does not check with requested value Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r1423ma.log.tsy1.ntup nt1= 7 st1= 1u tt= 1 set scale tsys1 [2] min max 111.7 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 131.7 in match_chan ft1= r1423ma.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 111.7 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 107.7 ymax 235.9 in match_chan ft1= r1423ma.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 111.7 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 11.7 ymax 305