Starting generation of Calibration File FS version = 0009.0010.0004 time_zero = 13669200 Found #19 errors of type = ERROR ch -4 Device vf timed-out on response from MATCN Found #10 errors of type = ERROR ma -4 Device vf timed-out on response. Found #2 errors of type = ERROR ch -4 Device v4 timed-out on response from MATCN Found #2 errors of type = ERROR ma -4 Device v4 timed-out on response. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR ch -302 vf frequency does not check with requested value Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR ch -304 vf TPI selection does not check with requested setting Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector i3. Found #1 errors of type = ERROR ch -303 vf bandwidth does not check with requested value Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector i3. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector i1. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR ch -307 vf unlock indicator is on Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 1u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR ch -309 vf alarm is on Found #1 errors of type = ERROR ch -305 vf USB attenuator does not check with requested setting Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 2u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector i1. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR ch -306 vf LSB attenuator does not check with requested setting Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 2u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 1u. Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these SK parameters: 00(BXFNT) 02(LO_TMP) 03(DCAL_T) RX1 min= 24.40 max= 24.80 RX2 min= 47.80 max= 48.10 RX3 min= 36.80 max= 37.10 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= k10158ny.log.tsy1.ntup nt1= 7 st1= 1u tt= 1 set scale tsys1 [2] min max 57.4 69.5 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 73.6 in match_chan ft1= k10158ny.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 57.4 69.5 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 49.9 ymax 73 in match_chan ft1= k10158ny.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 57.4 69.5 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 23.2 ymax 121.6