Starting generation of Calibration File FS version = 0009.0010.0004 time_zero = 9435600 Found #6 errors of type = ERROR ma -4 Device v4 timed-out on response. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector i3. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector i3. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector i1. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 1u. Found #1 errors of type = ERROR qs -203 Error specifying declination. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 2u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector i1. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 2u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 1u. Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these SK parameters: 00(BXFNT) 02(LO_TMP) 03(DCAL_T) RX1 min= 22.50 max= 24.10 RX2 min= 47.70 max= 47.80 RX3 min= 35.10 max= 35.60 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= k10109ny.log.tsy1.ntup nt1= 7 st1= 1u tt= 1 set scale tsys1 [2] min max 54.9 66.9 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 72.4 in match_chan ft1= k10109ny.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 54.9 66.9 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 47.5 ymax 69.7 in match_chan ft1= k10109ny.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 54.9 66.9 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 65.2 ymax 116.8