Starting generation of Calibration File 
FS version = 0009.0010.0003 
time_zero = 30362400 
Found #238 errors of type = ERROR qk -211 Tsys value for device bu overflowed or was less than zero. 
Found #120 errors of type = ERROR m5  -21 mk5cn: error connect(): mk5 device connection open timed-out 
Found #8 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! 
Found #6 errors of type = ERROR sp   -4 Unrecognized name (not a function or procedure). 
Found #2 errors of type = ERROR m5 -900 Already off 
Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request 
Found #1 errors of type = ERROR un  115 Operation now in progress 
Found #1 errors of type = ERROR m5  -23 mk5cn: socket open error from getsockopt() 
Found these BBCs: bbc01 bbc05 bbc09
NBBC: 3
Found these  parameters:   
RX1 min= 100000 max= -1
RX2 min= 100000 max= -1
RX3 min= 100000 max= -1
Plotting 3 Tsys channels: 01 05 09
Tsys values are: -1 1 2 etc
NTSYS: 3
in match_chan ft1= t2059mh.log.tsy1.ntup nt1= 8 st1= 1u tt= 1
set scale tsys1 [2] min max 69.0 208.0
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 66.1 ymax 219.6 
in match_chan ft1= t2059mh.log.tsy1.ntup nt1= 12 st1= 5u tt= 1
set scale tsys1 [2] min max 69.0 208.0
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 71 ymax 247.7 
in match_chan ft1= t2059mh.log.tsy1.ntup nt1= 18 st1= 9u tt= 1
set scale tsys1 [2] min max 69.0 208.0
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 152.8 ymax 211.1