Starting generation of Calibration File FS version = 0009.0010.0003 time_zero = 28720800 Found #294 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #294 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #194 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #51 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #34 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #32 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #30 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #29 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #29 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #24 errors of type = ERROR st -100 invalid time in antenna message - antenna protocol error. Found #24 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #23 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #20 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #14 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #12 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #9 errors of type = ERROR ch -308 v7 total power integrator overflow Found #7 errors of type = ERROR ch -308 v8 total power integrator overflow Found #6 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #4 errors of type = ERROR ch -308 vb total power integrator overflow Found #4 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #2 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 6u. Found #2 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 4u. Found #2 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 1u. Found #2 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 5u. Found #2 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 8d. Found #2 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 3u. Found #2 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 5u. Found #2 errors of type = ERROR qn -201 Error in request. Unknown module or does not match your equipment. Found #2 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 8d. Found #2 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector i3. Found #2 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 7u. Found #2 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector i3. Found #2 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector i1. Found #2 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 6u. Found #2 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #2 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 7u. Found #2 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 4u. Found #2 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 3u. Found #2 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 2u. Found #2 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector i1. Found #2 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 2u. Found #2 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 1u. Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR ch -302 v6 frequency does not check with requested value Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR m5 -900 Check formatter serial number even Found #1 errors of type = ERROR m5 -900 No scans Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= euro96sv.log.tsy1.ntup nt1= 7 st1= 1u tt= 1 set scale tsys1 [2] min max 13.4 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 7.7 ymax 305 in match_chan ft1= euro96sv.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 13.4 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 39.5 ymax 305 in match_chan ft1= euro96sv.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 13.4 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 1.4 ymax 305