Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 16650000 Found #914 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #453 errors of type = ERROR ch -309 ve alarm is on Found #453 errors of type = ERROR ch -309 vd alarm is on Found #413 errors of type = ERROR ch -309 v3 alarm is on Found #303 errors of type = ERROR ch -309 v4 alarm is on Found #299 errors of type = ERROR ch -309 vc alarm is on Found #298 errors of type = ERROR ch -309 v5 alarm is on Found #287 errors of type = ERROR ch -309 v7 alarm is on Found #279 errors of type = ERROR ch -309 v1 alarm is on Found #279 errors of type = ERROR ch -309 v2 alarm is on Found #247 errors of type = ERROR ch -309 v6 alarm is on Found #232 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #185 errors of type = ERROR ch -309 v8 alarm is on Found #143 errors of type = ERROR ch -303 v9 bandwidth does not check with requested value Found #143 errors of type = ERROR ch -302 va frequency does not check with requested value Found #143 errors of type = ERROR ch -309 v9 alarm is on Found #143 errors of type = ERROR ch -302 v9 frequency does not check with requested value Found #143 errors of type = ERROR ch -303 va bandwidth does not check with requested value Found #143 errors of type = ERROR ch -305 v9 USB attenuator does not check with requested setting Found #143 errors of type = ERROR ch -306 v9 LSB attenuator does not check with requested setting Found #143 errors of type = ERROR ch -309 va alarm is on Found #142 errors of type = ERROR ch -306 va LSB attenuator does not check with requested setting Found #142 errors of type = ERROR ch -305 va USB attenuator does not check with requested setting Found #129 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #108 errors of type = ERROR ch -307 va unlock indicator is on Found #99 errors of type = ERROR ch -307 v9 unlock indicator is on Found #62 errors of type = ERROR ch -309 vb alarm is on Found #47 errors of type = ERROR ch -302 vd frequency does not check with requested value Found #41 errors of type = ERROR ch -307 vd unlock indicator is on Found #37 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #35 errors of type = ERROR ch -305 v7 USB attenuator does not check with requested setting Found #35 errors of type = ERROR ch -302 v7 frequency does not check with requested value Found #35 errors of type = ERROR ch -303 v7 bandwidth does not check with requested value Found #35 errors of type = ERROR ch -306 v7 LSB attenuator does not check with requested setting Found #35 errors of type = ERROR ch -303 v8 bandwidth does not check with requested value Found #35 errors of type = ERROR ch -302 v8 frequency does not check with requested value Found #34 errors of type = ERROR ch -306 v8 LSB attenuator does not check with requested setting Found #34 errors of type = ERROR ch -305 v8 USB attenuator does not check with requested setting Found #25 errors of type = ERROR ch -307 v8 unlock indicator is on Found #22 errors of type = ERROR ch -307 v7 unlock indicator is on Found #17 errors of type = ERROR ch -303 vd bandwidth does not check with requested value Found #11 errors of type = ERROR ch -302 v5 frequency does not check with requested value Found #11 errors of type = ERROR ch -305 v5 USB attenuator does not check with requested setting Found #11 errors of type = ERROR ch -306 v5 LSB attenuator does not check with requested setting Found #11 errors of type = ERROR ch -303 v5 bandwidth does not check with requested value Found #10 errors of type = ERROR ch -307 v5 unlock indicator is on Found #9 errors of type = ERROR ST -1 Trouble with class buffer in fixtmp Found #8 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #6 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #5 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #5 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #5 errors of type = ERROR q1 -303 VC patching not defined. Found #4 errors of type = ERROR ch -365 IF3 switch 2 setting does not check with request. Found #4 errors of type = ERROR ch -364 IF3 switch 1 setting does not check with request. Found #4 errors of type = ERROR ch -361 IF3 module is not in remote Found #4 errors of type = ERROR m5 -904 MARK5 return code 4: error encountered (during attempt to execute) Found #4 errors of type = ERROR ch -368 IF3 frequency does not check with equip.ctl value. Found #3 errors of type = ERROR ch -311 IF distributor is not in remote Found #3 errors of type = ERROR ma -4 Device v1 timed-out on response. Found #2 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #2 errors of type = ERROR m5 -900 Not while recording or playing Found #2 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #2 errors of type = ERROR m5 -900 Previous recording still active Found #2 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #2 errors of type = ERROR bo -173 Disk recording was commanded either use disk_record off or terminate disk_record_ok. Found #2 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #2 errors of type = ERROR m5 -900 Can't get device info Found #2 errors of type = ERROR m5 -900 Can't get SS version Found #2 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #1 errors of type = ERROR qi -201 IF1 attenuator must be MAX OLD or between 0 and 63 Found #1 errors of type = ERROR ch -307 ve unlock indicator is on Found #1 errors of type = ERROR m5 -900 Check formatter serial number even Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 3 4 -1 etc NTSYS: 3 in match_chan ft1= rd0705on.log.tsy1.ntup nt1= 18 st1= 1d tt= 1 set scale tsys1 [2] min max 31.9 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305 in match_chan ft1= rd0705on.log.tsy1.ntup nt1= 13 st1= 5d tt= 1 set scale tsys1 [2] min max 31.9 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 18.1 ymax 305 in match_chan ft1= rd0705on.log.tsy1.ntup nt1= 20 st1= 9d tt= 1 set scale tsys1 [2] min max 31.9 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305