Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 15433200 Found #1417 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #480 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #268 errors of type = ERROR ma -4 Device rx timed-out on response. Found #120 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #59 errors of type = ERROR m5 -104 mk5cn: time-out on mk5 device connection closed Found #47 errors of type = ERROR ch -4 Device rx timed-out on response from MATCN Found #29 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #16 errors of type = ERROR un 115 Operation now in progress Found #16 errors of type = ERROR m5 -23 mk5cn: socket open error from getsockopt() Found #12 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #12 errors of type = ERROR m5 -904 MARK5 return code 4: error encountered (during attempt to execute) Found #10 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #10 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #10 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #10 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #8 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #8 errors of type = ERROR m5 -900 Probably no such disk Found #8 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #8 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #8 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #8 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #8 errors of type = ERROR ST -1 Trouble with class buffer in fixtmp Found #6 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #2 errors of type = ERROR 5k -601 SCAN_CHECK failed Found #2 errors of type = ERROR m5 -900 Already off Found #2 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #2 errors of type = ERROR m5 -900 Can't get bank status Found #1 errors of type = ERROR ch -308 v9 total power integrator overflow Found #1 errors of type = ERROR m5 -900 Can't XLRStop() Found #1 errors of type = ERROR AN -5 Error return from antenna. Found #1 errors of type = ERROR m5 -900 Can't get record length Found #1 errors of type = ERROR g1 1 Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02 03 0e RX1 min= 100000 max= 2007.178.17:13:51.50 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= rd0704on.log.tsy1.ntup nt1= 7 st1= 1d tt= 1 set scale tsys1 [2] min max 73.9 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 76.4 ymax 305 in match_chan ft1= rd0704on.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 73.9 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 71.3 ymax 305 in match_chan ft1= rd0704on.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 73.9 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 102 ymax 305