Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 31251600 Found #264 errors of type = ERROR ma -4 Device de timed-out on response. Found #53 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #18 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #15 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #14 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #14 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #14 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #14 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #13 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #13 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #12 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #12 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #12 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #12 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #11 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #11 errors of type = ERROR ma -4 Device if timed-out on response. Found #10 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #10 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #10 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #10 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #6 errors of type = ERROR ch -4 Device if timed-out on response from MATCN Found #2 errors of type = ERROR ch -308 ve total power integrator overflow Found #2 errors of type = ERROR ch -308 v9 total power integrator overflow Found #2 errors of type = ERROR ch -308 va total power integrator overflow Found #2 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR ch -301 v1 module is not in remote Found #1 errors of type = ERROR ch -363 IF3 mixer state does not check with request. Found #1 errors of type = ERROR ch -302 v4 frequency does not check with requested value Found #1 errors of type = ERROR ch -307 v2 unlock indicator is on Found #1 errors of type = ERROR ch -307 v4 unlock indicator is on Found #1 errors of type = ERROR ch -308 vc total power integrator overflow Found #1 errors of type = ERROR ch -308 v5 total power integrator overflow Found #1 errors of type = ERROR ch -309 v4 alarm is on Found #1 errors of type = ERROR ch -304 v2 TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -303 v3 bandwidth does not check with requested value Found #1 errors of type = ERROR ch -365 IF3 switch 2 setting does not check with request. Found #1 errors of type = ERROR ch -306 v3 LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #1 errors of type = ERROR ch -308 v6 total power integrator overflow Found #1 errors of type = ERROR ch -302 v3 frequency does not check with requested value Found #1 errors of type = ERROR ch -303 v2 bandwidth does not check with requested value Found #1 errors of type = ERROR ch -305 v3 USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -308 vd total power integrator overflow Found #1 errors of type = ERROR ch -304 v3 TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -303 v4 bandwidth does not check with requested value Found #1 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #1 errors of type = ERROR ch -302 v2 frequency does not check with requested value Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 43.04 max= 44.99 RX2 min= 38.88 max= 40.35 RX3 min= 0.150 max= 0.152 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r4308ft.log.tsy1.ntup nt1= 7 st1= 1d tt= 1 set scale tsys1 [2] min max 1.6 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305 in match_chan ft1= r4308ft.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 1.6 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 23.6 ymax 305 in match_chan ft1= r4308ft.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 1.6 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305