Starting generation of Calibration File 
FS version = 0009.0009.0002 
time_zero = 30049200 
Found #6 errors of type = ERROR st   -7 Antenna off-source! 
Found #2 errors of type = ERROR st   -6 Antenna control restored. 
Found #2 errors of type = ERROR st   -4 Interface not set to remote. 
Found #1 errors of type = ERROR mc   -2 Interface ba responded  but did not ACKnowledge. 
Found #1 errors of type = ERROR m5 -900 Check formatter serial number even 
Found #1 errors of type = ERROR st   -2 Antenna timed out. 
Found #1 errors of type = ERROR an   -7 Antenna communications restored. 
Found #1 errors of type = ERROR mc   -2 Interface bd responded  but did not ACKnowledge. 
Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request 
Found these BBCs: bbc01 bbc05 bbc09
NBBC: 3
Found these SX parameters: slo xlo sup
RX1 min= 3.89 max= 3.92
RX2 min= 4.80 max= 4.87
RX3 min= 275.04 max= 284.32
Plotting 3 Tsys channels: 01 05 09
Tsys values are: -1 1 2 etc
NTSYS: 3
in match_chan ft1= r4306kk.log.tsy1.ntup nt1= 8 st1= 1u tt= 1
set scale tsys1 [2] min max 41.6 111.5
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 35.3 ymax 119.5 
in match_chan ft1= r4306kk.log.tsy1.ntup nt1= 20 st1= 5u tt= 1
set scale tsys1 [2] min max 41.6 111.5
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 25.4 ymax 97.1 
in match_chan ft1= r4306kk.log.tsy1.ntup nt1= 13 st1= 9u tt= 1
set scale tsys1 [2] min max 41.6 111.5
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 28.3 ymax 106.2