Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 24602400 Found #88 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #18 errors of type = ERROR st -14 Antenna stuck. Found #9 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #3 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #3 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #2 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 65K. Found #2 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #2 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 40K. Found #2 errors of type = ERROR ch -348 Receiver LO is unlocked. Found #1 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #1 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 43.52 max= 45.23 RX2 min= 39.13 max= 40.72 RX3 min= 0.150 max= 0.152 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r4297ft.log.tsy1.ntup nt1= 7 st1= 1d tt= 1 set scale tsys1 [2] min max -5 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 105.3 ymax 305 in match_chan ft1= r4297ft.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max -5 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305 in match_chan ft1= r4297ft.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max -5 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305