Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 19155600 Found #394 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #266 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #178 errors of type = ERROR ch -308 vc total power integrator overflow Found #148 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #148 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #50 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #34 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #30 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #28 errors of type = ERROR pt -102 [PTRAK] - LU has timed out. Continue tracking. Found #11 errors of type = ERROR pt -103 [PTRAK] - No response from LU . PTRAK aborted. Found #10 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #6 errors of type = ERROR ch -304 v6 TPI selection does not check with requested setting Found #6 errors of type = ERROR ch -306 v6 LSB attenuator does not check with requested setting Found #6 errors of type = ERROR ch -303 v6 bandwidth does not check with requested value Found #6 errors of type = ERROR ch -308 vb total power integrator overflow Found #4 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #3 errors of type = ERROR ch -307 vd unlock indicator is on Found #3 errors of type = ERROR ch -309 v5 alarm is on Found #3 errors of type = ERROR ch -306 v3 LSB attenuator does not check with requested setting Found #3 errors of type = ERROR ch -302 vd frequency does not check with requested value Found #3 errors of type = ERROR ch -303 v3 bandwidth does not check with requested value Found #3 errors of type = ERROR ch -302 vb frequency does not check with requested value Found #3 errors of type = ERROR ch -306 ve LSB attenuator does not check with requested setting Found #3 errors of type = ERROR ch -306 vd LSB attenuator does not check with requested setting Found #3 errors of type = ERROR ch -306 vb LSB attenuator does not check with requested setting Found #3 errors of type = ERROR ch -309 ve alarm is on Found #3 errors of type = ERROR ch -309 vd alarm is on Found #3 errors of type = ERROR ch -304 vb TPI selection does not check with requested setting Found #3 errors of type = ERROR ch -304 vd TPI selection does not check with requested setting Found #3 errors of type = ERROR ch -307 v3 unlock indicator is on Found #3 errors of type = ERROR ch -302 ve frequency does not check with requested value Found #3 errors of type = ERROR ch -307 v5 unlock indicator is on Found #3 errors of type = ERROR ch -305 vb USB attenuator does not check with requested setting Found #3 errors of type = ERROR ch -303 vb bandwidth does not check with requested value Found #3 errors of type = ERROR ch -303 vd bandwidth does not check with requested value Found #3 errors of type = ERROR ch -304 ve TPI selection does not check with requested setting Found #3 errors of type = ERROR ch -303 ve bandwidth does not check with requested value Found #3 errors of type = ERROR ch -302 v3 frequency does not check with requested value Found #3 errors of type = ERROR ch -309 v3 alarm is on Found #3 errors of type = ERROR ch -304 v3 TPI selection does not check with requested setting Found #3 errors of type = ERROR st -36 The antenna is not in operating mode. Found #3 errors of type = ERROR ch -307 ve unlock indicator is on Found #2 errors of type = ERROR ch -309 vf alarm is on Found #2 errors of type = ERROR bo -173 Disk recording was commanded either use disk_record off or terminate disk_record_ok. Found #1 errors of type = ERROR ch -305 vf USB attenuator does not check with requested setting Found #1 errors of type = ERROR sp -3 More than 12 characters in function or procedure name. Found #1 errors of type = ERROR ch -303 vf bandwidth does not check with requested value Found #1 errors of type = ERROR ch -308 v9 total power integrator overflow Found #1 errors of type = ERROR ma -4 Device v3 timed-out on response. Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR st -105 [ANCOM] - Too many errors from LU . Found #1 errors of type = ERROR ch -304 vf TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -302 vf frequency does not check with requested value Found #1 errors of type = ERROR m5 -900 No scans Found #1 errors of type = ERROR qv -201 Video converter frequency must be between 100 and 500 MHz. Found #1 errors of type = ERROR ch -306 vf LSB attenuator does not check with requested setting Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r4288ma.log.tsy1.ntup nt1= 7 st1= 1d tt= 1 set scale tsys1 [2] min max 44.5 93.6 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 35.9 ymax 105.8 in match_chan ft1= r4288ma.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 44.5 93.6 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 45.5 ymax 122.4 in match_chan ft1= r4288ma.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 44.5 93.6 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 30.4 ymax 305