Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 14302800 Found #695 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #34 errors of type = ERROR ch -308 v1 total power integrator overflow Found #23 errors of type = ERROR st -100 invalid time in antenna message - antenna protocol error. Found #14 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #7 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #6 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #6 errors of type = ERROR AN -4 Interface not set to remote. Found #4 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #2 errors of type = ERROR sc -13 setcl: formatter to FS time difference 0.5 seconds or greater Found #2 errors of type = ERROR st -100 wrong OK STOP message - antenna protocol error. Found #2 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #1 errors of type = ERROR qs -102 No default for right ascension. Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r4280sv.log.tsy1.ntup nt1= 7 st1= 1d tt= 1 set scale tsys1 [2] min max 35.6 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 28.1 ymax 305 in match_chan ft1= r4280sv.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 35.6 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 32.7 ymax 305 in match_chan ft1= r4280sv.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 35.6 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 75.1 ymax 305