Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 7059600 Found #538 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #331 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #258 errors of type = ERROR ch -308 vc total power integrator overflow Found #234 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #206 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #118 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #84 errors of type = ERROR st -51 Verify error on FMUX command. Found #55 errors of type = ERROR st -115 [ANTCN] - WARNING: X S paths are not in line. Found #52 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #44 errors of type = ERROR ch -308 v9 total power integrator overflow Found #36 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #30 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #30 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #30 errors of type = ERROR st -105 [ANCOM] - Too many errors from LU . Found #28 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #26 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #24 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #24 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #22 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #22 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #22 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #21 errors of type = ERROR ch -308 va total power integrator overflow Found #18 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #16 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #3 errors of type = ERROR st -32 Limit on azimuth value. Found #3 errors of type = ERROR st -36 The antenna is not in operating mode. Found #1 errors of type = ERROR ch -308 vb total power integrator overflow Found #1 errors of type = ERROR ch -309 vb alarm is on Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r4268ma.log.tsy1.ntup nt1= 7 st1= 1d tt= 1 set scale tsys1 [2] min max 10.0 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 50.4 ymax 305 in match_chan ft1= r4268ma.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 10.0 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 41.5 ymax 305 in match_chan ft1= r4268ma.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 10.0 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 1.8 ymax 305