Starting generation of Calibration File 
FS version = 0009.0009.0002 
time_zero = 5245200 
Found #574 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. 
Found #301 errors of type = ERROR ch -317 Total power integrator overflow on IF2 
Found #297 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. 
Found #262 errors of type = ERROR ch -308 vc total power integrator overflow 
Found #258 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. 
Found #156 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. 
Found #82 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. 
Found #46 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! 
Found #15 errors of type = ERROR st  -51 Verify error on FMUX command. 
Found #13 errors of type = ERROR ch -308 v9 total power integrator overflow 
Found #10 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. 
Found #9 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. 
Found #8 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. 
Found #8 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. 
Found #8 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. 
Found #8 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. 
Found #8 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. 
Found #8 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. 
Found #7 errors of type = ERROR st -115 [ANTCN] - WARNING: X S paths are not in line. 
Found #6 errors of type = ERROR ch -308 va total power integrator overflow 
Found #6 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. 
Found #6 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. 
Found #6 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. 
Found #5 errors of type = ERROR st -105 [ANCOM] - Too many errors from LU      . 
Found #1 errors of type = ERROR ch -316 Total power integrator overflow on IF1 
Found #1 errors of type = ERROR ch -308 vb total power integrator overflow 
Found #1 errors of type = ERROR ch -308 v2 total power integrator overflow 
Found these BBCs: vc01 vc05 vc09
NBBC: 3
Found these  parameters:   
RX1 min= 100000 max= -1
RX2 min= 100000 max= -1
RX3 min= 100000 max= -1
Plotting 3 Tsys channels: 01 05 09
Tsys values are: 1 2 3 etc
NTSYS: 3
in match_chan ft1= r4265ma.log.tsy1.ntup nt1= 7 st1= 1d tt= 1
set scale tsys1 [2] min max 40.3 305
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 41.1 ymax 305 
in match_chan ft1= r4265ma.log.tsy1.ntup nt1= 19 st1= 5u tt= 1
set scale tsys1 [2] min max 40.3 305
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 40 ymax 305 
in match_chan ft1= r4265ma.log.tsy1.ntup nt1= 12 st1= 9u tt= 1
set scale tsys1 [2] min max 40.3 305
set scale tsys2 [2] min max  
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 11.5 ymax 305