Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 31172400 Found #161 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #153 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #135 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #133 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #121 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #118 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #113 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #112 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #111 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #107 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #107 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #105 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #105 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #105 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #101 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #99 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #97 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #18 errors of type = ERROR st -14 Antenna stuck. Found #16 errors of type = ERROR ch -348 Receiver LO is unlocked. Found #16 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 65K. Found #16 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #16 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 40K. Found #15 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #7 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #7 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #2 errors of type = ERROR ch -364 IF3 switch 1 setting does not check with request. Found #1 errors of type = ERROR m5 -900 No scans Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r1308ft.log.tsy1.ntup nt1= 7 st1= 1d tt= 1 set scale tsys1 [2] min max 67.4 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 61.7 ymax 305 in match_chan ft1= r1308ft.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 67.4 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 56 ymax 305 in match_chan ft1= r1308ft.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 67.4 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 163.6 ymax 305