Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 15861600 Found #48 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #17 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #8 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR ch -308 va total power integrator overflow Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR ib -4 GPIB Device time-out on response pp Found #1 errors of type = ERROR ch -348 Receiver LO is unlocked. Found #1 errors of type = ERROR m5 -900 Check formatter serial number even Found these BBCs: vc06 vc11 NBBC: 2 Found these RX parameters: front rear lo RX1 min= 100000 max= 2007.183.14:02:11.47 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 2 Tsys channels: 06 11 Tsys values are: 1 2 3 etc NTSYS: 2 in match_chan ft1= r1283ho.log.tsy1.ntup nt1= 20 st1= 6u tt= 1 set scale tsys1 [2] min max 56.2 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 41.7 ymax 305 in match_chan ft1= r1283ho.log.tsy1.ntup nt1= 14 st1= bu tt= 1 set scale tsys1 [2] min max 56.2 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 51.2 ymax 305