Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 15897600 Found #41 errors of type = ERROR q+ -302 Last commanded IF3 attenuation used as default please modify command. Found #41 errors of type = ERROR qi -302 Last commanded IFD attenuations used as default please modify command. Found #13 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #6 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #3 errors of type = ERROR ib -4 GPIB Device time-out on response ca Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #1 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #1 errors of type = ERROR m5 -900 No scans Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r1283ft.log.tsy1.ntup nt1= 7 st1= 1d tt= 1 set scale tsys1 [2] min max 128.1 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 112.7 ymax 305 in match_chan ft1= r1283ft.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 128.1 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 184.8 ymax 298.6 in match_chan ft1= r1283ft.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 128.1 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 90.4 ymax 121.9