Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 10598400 Found #1457 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #782 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #41 errors of type = ERROR ch -308 vb total power integrator overflow Found #37 errors of type = ERROR ch -308 vc total power integrator overflow Found #26 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #24 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #6 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #4 errors of type = ERROR ch -308 v8 total power integrator overflow Found #4 errors of type = ERROR ch -4 Device t1 timed-out on response from MATCN Found #3 errors of type = ERROR ch -309 v6 alarm is on Found #3 errors of type = ERROR ch -309 v3 alarm is on Found #3 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #3 errors of type = ERROR ch -309 v7 alarm is on Found #3 errors of type = ERROR ch -309 vb alarm is on Found #2 errors of type = ERROR m5 -900 Check formatter serial number even Found #2 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 30K. Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #2 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #2 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 60K. Found #1 errors of type = ERROR sp -3 More than 12 characters in function or procedure name. Found #1 errors of type = ERROR qn -201 Error in request. Unknown module or does not match your equipment. Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 23.87 max= 30.83 RX2 min= 28.38 max= 35.34 RX3 min= 1.416 max= 1.548 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r1274on.log.tsy1.ntup nt1= 7 st1= 1d tt= 1 set scale tsys1 [2] min max 141.9 190.6 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 138.5 ymax 201.7 in match_chan ft1= r1274on.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 141.9 190.6 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 121.5 ymax 178.2 in match_chan ft1= r1274on.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 141.9 190.6 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 77.4 ymax 305