Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 3769200 Found #2682 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #826 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #75 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 30K. Found #75 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 60K. Found #46 errors of type = ERROR ch -308 vc total power integrator overflow Found #40 errors of type = ERROR ch -308 vb total power integrator overflow Found #22 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #19 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #14 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #7 errors of type = ERROR ch -308 v9 total power integrator overflow Found #6 errors of type = ERROR m5 -23 mk5cn: socket open error from getsockopt() Found #6 errors of type = ERROR un 115 Operation now in progress Found #4 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #4 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #2 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #1 errors of type = ERROR m5 -900 Check formatter serial number even Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR bo -133 Error opening procedure library Found #1 errors of type = ERROR sc -13 setcl: formatter to FS time difference 0.5 seconds or greater Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 31.44 max= 35.47 RX2 min= 36.32 max= 39.49 RX3 min= 1.383 max= 1.466 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r1263on.log.tsy1.ntup nt1= 7 st1= 1d tt= 1 set scale tsys1 [2] min max 119.8 291.4 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 106.5 ymax 305 in match_chan ft1= r1263on.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 119.8 291.4 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 100.4 ymax 305 in match_chan ft1= r1263on.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 119.8 291.4 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 65 ymax 305