Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 1364400 Found #3 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #2 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #1 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 40K. Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR m5 -900 No scans Found #1 errors of type = ERROR st -14 Antenna stuck. Found #1 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 65K. Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r1259ft.log.tsy1.ntup nt1= 7 st1= 1d tt= 1 set scale tsys1 [2] min max 64.4 108.6 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 58.3 ymax 111.9 in match_chan ft1= r1259ft.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 64.4 108.6 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 66.2 ymax 114.8 in match_chan ft1= r1259ft.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 64.4 108.6 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 27.4 ymax 182.1