Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 21290400 Found #1473 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #496 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #251 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #168 errors of type = ERROR ma -4 Device rx timed-out on response. Found #147 errors of type = ERROR ch -4 Device rx timed-out on response from MATCN Found #13 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #11 errors of type = ERROR ST -1 Trouble with class buffer in fixtmp Found #6 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #5 errors of type = ERROR ch -304 v6 TPI selection does not check with requested setting Found #5 errors of type = ERROR ch -306 v6 LSB attenuator does not check with requested setting Found #5 errors of type = ERROR ch -307 v6 unlock indicator is on Found #5 errors of type = ERROR ch -302 v6 frequency does not check with requested value Found #5 errors of type = ERROR ch -303 v6 bandwidth does not check with requested value Found #5 errors of type = ERROR ch -309 v6 alarm is on Found #4 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #3 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #2 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #2 errors of type = ERROR ch -309 v8 alarm is on Found #2 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #2 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #1 errors of type = ERROR m5 -900 Check formatter serial number even Found #1 errors of type = ERROR m5 -900 Can't do calculations Found #1 errors of type = ERROR ch -371 IF3 alarm is on Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02 03 0e RX1 min= 100000 max= 2007.246.13:46:57.80 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= euro89on.log.tsy1.ntup nt1= 7 st1= 1d tt= 1 set scale tsys1 [2] min max 73.9 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 75 ymax 305 in match_chan ft1= euro89on.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 73.9 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 71.7 ymax 305 in match_chan ft1= euro89on.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 73.9 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 300 ymax 305