Starting generation of Calibration File FS version = 0009.0004.0018 time_zero = 22006800 Rack type is MK3/4 Found #607 errors of type = ERROR ma -4 Device v5 timed-out on response. Found #422 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #391 errors of type = ERROR ch -351 Tape head 1 is not in requested position. Found #303 errors of type = ERROR qi -201 IF1 attenuator must be MAX OLD or between 0 and 63 Found #303 errors of type = ERROR q+ -201 if3 attenuation must be one of 0 ... 63 max or old. Found #302 errors of type = ERROR qs -306 WARNING: ANTCN not being run antenna device is dev null. Found #48 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #32 errors of type = ERROR ma -4 Device rx timed-out on response. Found #24 errors of type = ERROR qb -201 Error specifying A D channel. Can be 0 to 1F or code word. Found #14 errors of type = ERROR ch -329 Formatter time does not agree with Field System time. Found #14 errors of type = ERROR ch -311 IF distributor is not in remote Found #14 errors of type = ERROR ch -4 Device rx timed-out on response from MATCN Found #9 errors of type = ERROR ch -301 v5 module is not in remote Found #9 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #8 errors of type = ERROR ch -4 Device v5 timed-out on response from MATCN Found #4 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #3 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #3 errors of type = ERROR ch -327 Formatter's run set switch is in SET position Found #3 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #2 errors of type = ERROR ch -334 Tape should be moving and it's stopped Found #1 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #1 errors of type = ERROR qn -201 Error in request. Must be ALL EVEN ODD IF FM TP V1...V15 HD RX. Found #1 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found these BBCs: NBBC: 0 Found these RX parameters: lo dcal lo5mhz RX1 min= 100000 max= 2007.254.17:17:38.00 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 0 Tsys channels: NTSYS: 0