Starting generation of Calibration File FS version = 0009.0007.0005 time_zero = 28846800 Found #175 errors of type = ERROR qk -211 Tsys value for device ic overflowed or was less than zero. Found #23 errors of type = ERROR 4f -501 Formatter was failing the synch test. Found #6 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #6 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #5 errors of type = ERROR qk -211 Tsys value for device 1u overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device eu overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device 2u overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device 3u overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device 4u overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device 5u overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device 6u overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device du overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device ib overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device cu overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device 7u overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device bu overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device au overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device 8u overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device 9u overflowed or was less than zero. Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR m5 -900 Check formatter serial number even Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR ma -4 Device fm timed-out on response. Found #1 errors of type = ERROR ma -701 MK4 DE unknown command Found these BBCs: bbc02 bbc06 bbc11 NBBC: 3 Found these RX parameters: 00(front) 02(lo) 03(dcal) RX1 min= 19.71 max= 2005.333.21:32:39.45 RX2 min= 30.34 max= 33.63 RX3 min= 29.97 max= 33.15 Plotting 3 Tsys channels: 02 06 11 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= t2041gc.log.tsy1.ntup nt1= 8 st1= 2u tt= 1 set scale tsys1 [2] min max 183.1 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 187 ymax 305 in match_chan ft1= t2041gc.log.tsy1.ntup nt1= 12 st1= 6u tt= 1 set scale tsys1 [2] min max 183.1 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 173.8 ymax 305 in match_chan ft1= t2041gc.log.tsy1.ntup nt1= 17 st1= bu tt= 1 set scale tsys1 [2] min max 183.1 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 88.8 ymax 305