Starting generation of Calibration File FS version = 0009.0007.0007 time_zero = 15620400 Found #403 errors of type = ERROR ma -4 Device rx timed-out on response. Found #131 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #91 errors of type = ERROR ch -4 Device rx timed-out on response from MATCN Found #20 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #19 errors of type = ERROR ch -332 Tape drive is not in remote Found #15 errors of type = ERROR ST -4 Error in antenna communication Found #13 errors of type = ERROR ch -334 Tape should be moving and it's stopped Found #6 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #3 errors of type = ERROR ch -340 Reproduce track A does not check with request Found #3 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #3 errors of type = ERROR qg -303 Track 29 parity errors exceed threshold. Found #3 errors of type = ERROR ch -341 Reproduce track B does not check with request Found #3 errors of type = ERROR ch -346 Record enable is in the wrong state. Found #3 errors of type = ERROR ch -338 Reproduce equalizer does not check with request Found #3 errors of type = ERROR qg -303 Track 32 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 30 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 31 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 33 parity errors exceed threshold. Found #2 errors of type = ERROR 4f -201 Mode must be one of: a b1 b2 c1 c2 d1 ... d28 e1 ... e4. Found #1 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #1 errors of type = ERROR sp -13 This command not supported for your equipment check equip.ctl. Found #1 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 18 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #1 errors of type = ERROR qg -303 Track 26 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 16 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #1 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #1 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #1 errors of type = ERROR qk -303(rx) Found #1 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 2 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 4 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #1 errors of type = ERROR qg -303 Track 6 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 8 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #1 errors of type = ERROR sc -4 setcl: formatter to cpu time difference greater than 248 days Found #1 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #1 errors of type = ERROR qg -303 Track 10 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 20 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #1 errors of type = ERROR qg -303 Track 12 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 28 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 22 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 14 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #1 errors of type = ERROR qa -201 Tape number must be 8 charaters. Found #1 errors of type = ERROR qg -303 Track 24 parity errors exceed threshold. Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 35.59 max= 36.32 RX2 min= 47.43 max= 47.68 RX3 min= 2.500 max= 2.500 Can't plot RX3 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: etc Tsys2 values are: etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= nt1= st1= tt= set scale tsys1 [2] min max set scale tsys2 [2] min max set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100