Starting generation of Calibration File FS version = 0009.0007.0007 time_zero = 15613200 Found #79 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #22 errors of type = ERROR qg -303 Track 26 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 32 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 18 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 28 parity errors exceed threshold. Found #22 errors of type = ERROR ma -811 MK4 FM A D converter vs. mode conflict Found #22 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 22 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 12 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 30 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 20 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 29 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 10 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 8 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 2 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 4 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 6 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 31 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 33 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 16 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 24 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 14 parity errors exceed threshold. Found #22 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #6 errors of type = ERROR qk -211 Tsys value for device 4u overflowed or was less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device 3u overflowed or was less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device 6u overflowed or was less than zero. Found #5 errors of type = ERROR ch -233 r1 tape drive should be moving and it isn't Found #5 errors of type = ERROR qg -304 Track 21 sync errors exceed threshold. Found #4 errors of type = ERROR qk -211 Tsys value for device 5u overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device eu overflowed or was less than zero. Found #4 errors of type = ERROR qg -304 Track 5 sync errors exceed threshold. Found #4 errors of type = ERROR qk -211 Tsys value for device du overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device au overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device 9u overflowed or was less than zero. Found #4 errors of type = ERROR qg -304 Track 27 sync errors exceed threshold. Found #3 errors of type = ERROR qg -304 Track 13 sync errors exceed threshold. Found #2 errors of type = ERROR qk -211 Tsys value for device 8u overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device 2u overflowed or was less than zero. Found #2 errors of type = ERROR qg -304 Track 25 sync errors exceed threshold. Found #2 errors of type = ERROR qk -211 Tsys value for device 1u overflowed or was less than zero. Found #2 errors of type = ERROR qg -304 Track 15 sync errors exceed threshold. Found #2 errors of type = ERROR qg -304 Track 11 sync errors exceed threshold. Found #2 errors of type = ERROR qk -211 Tsys value for device cu overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device 7u overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device bu overflowed or was less than zero. Found #1 errors of type = ERROR rc -1 Tape drive has no vacuum. Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR qg -304 Track 3 sync errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 9 sync errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 23 sync errors exceed threshold. Found these BBCs: NBBC: 0 Found these RX parameters: 00(BXFNT_) 01(IF_PLT) 03(DCAL_T) RX1 min= 18.20 max= 19.70 RX2 min= 17.60 max= 20.30 RX3 min= 42.40 max= 42.90 Plotting 0 Tsys channels: Tsysa values are: etc Tsysb values are: etc Tsysc values are: etc Tsysd values are: etc NTSYS: 0