Starting generation of Calibration File FS version = 0009.0006.0009 time_zero = 10170000 Found #162 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #28 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #11 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #10 errors of type = ERROR ch -308 v9 total power integrator overflow Found #9 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #8 errors of type = ERROR ch -334 Tape should be moving and it's stopped Found #6 errors of type = ERROR ch -348 Receiver LO is unlocked. Found #5 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #5 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #4 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #3 errors of type = ERROR ch -342 Tape is not in ready state (vacuum not ready) Found #3 errors of type = ERROR qg -303 Track 31 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 26 parity errors exceed threshold. Found #3 errors of type = ERROR ch -309 va alarm is on Found #3 errors of type = ERROR qg -303 Track 32 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 30 parity errors exceed threshold. Found #2 errors of type = ERROR ch -308 v4 total power integrator overflow Found #2 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #2 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #2 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #2 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #2 errors of type = ERROR qg -303 Track 12 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 22 parity errors exceed threshold. Found #2 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #1 errors of type = ERROR qg -303 Track 24 parity errors exceed threshold. Found #1 errors of type = ERROR qg -313 Error decoding Mark IV decoder dqa response. Found #1 errors of type = ERROR ch -303 v9 bandwidth does not check with requested value Found #1 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #1 errors of type = ERROR ch -309 v9 alarm is on Found #1 errors of type = ERROR qa -202 Check label doesn't match. Check it and try again. Found #1 errors of type = ERROR ch -301 vd module is not in remote Found #1 errors of type = ERROR ch -301 ve module is not in remote Found #1 errors of type = ERROR ch -306 v9 LSB attenuator does not check with requested setting Found #1 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #1 errors of type = ERROR ch -301 va module is not in remote Found #1 errors of type = ERROR q< -301 Vacuum is not ready. Found #1 errors of type = ERROR ch -309 vd alarm is on Found #1 errors of type = ERROR qg -303 Track 20 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 18 parity errors exceed threshold. Found #1 errors of type = ERROR ch -304 v9 TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -302 v9 frequency does not check with requested value Found #1 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #1 errors of type = ERROR ch -305 v9 USB attenuator does not check with requested setting Found #1 errors of type = ERROR qg -303 Track 33 parity errors exceed threshold. Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these RX parameters: 00(FRONT) 01(REAR) 02(LO) RX1 min= 8.730 max= 16.91 RX2 min= 15.07 max= 22.28 RX3 min= 15.32 max= 22.40 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: etc Tsys2 values are: etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= nt1= st1= tt= set scale tsys1 [2] min max set scale tsys2 [2] min max set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100