Starting generation of Calibration File FS version = 0009.0007.0007 time_zero = 18126000 Found #192 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 30K. Found #156 errors of type = ERROR ma -4 Device rx timed-out on response. Found #127 errors of type = ERROR ch -4 Device rx timed-out on response from MATCN Found #54 errors of type = ERROR ch -4 Device ve timed-out on response from MATCN Found #53 errors of type = ERROR ch -371 IF3 alarm is on Found #51 errors of type = ERROR ch -301 va module is not in remote Found #49 errors of type = ERROR ch -301 vd module is not in remote Found #49 errors of type = ERROR ch -4 Device v3 timed-out on response from MATCN Found #48 errors of type = ERROR ch -4 Device v6 timed-out on response from MATCN Found #48 errors of type = ERROR ch -361 IF3 module is not in remote Found #46 errors of type = ERROR ch -311 IF distributor is not in remote Found #42 errors of type = ERROR ch -4 Device v5 timed-out on response from MATCN Found #42 errors of type = ERROR ch -4 Device v9 timed-out on response from MATCN Found #40 errors of type = ERROR ch -4 Device vc timed-out on response from MATCN Found #33 errors of type = ERROR ch -4 Device v7 timed-out on response from MATCN Found #32 errors of type = ERROR ch -4 Device v2 timed-out on response from MATCN Found #32 errors of type = ERROR ch -4 Device v8 timed-out on response from MATCN Found #32 errors of type = ERROR ch -4 Device v4 timed-out on response from MATCN Found #31 errors of type = ERROR ch -303 vb bandwidth does not check with requested value Found #31 errors of type = ERROR ch -304 vb TPI selection does not check with requested setting Found #31 errors of type = ERROR ch -302 vb frequency does not check with requested value Found #30 errors of type = ERROR ch -4 Device v1 timed-out on response from MATCN Found #28 errors of type = ERROR ch -303 v2 bandwidth does not check with requested value Found #28 errors of type = ERROR ch -304 v2 TPI selection does not check with requested setting Found #28 errors of type = ERROR ch -307 vb unlock indicator is on Found #28 errors of type = ERROR ch -301 vb module is not in remote Found #27 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #25 errors of type = ERROR ma -8(fm) Found #25 errors of type = ERROR ch -302 v2 frequency does not check with requested value Found #25 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #24 errors of type = ERROR ch -303 v4 bandwidth does not check with requested value Found #24 errors of type = ERROR ch -304 v4 TPI selection does not check with requested setting Found #24 errors of type = ERROR ch -302 v4 frequency does not check with requested value Found #23 errors of type = ERROR ch -302 v7 frequency does not check with requested value Found #23 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #23 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #22 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #22 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #22 errors of type = ERROR ch -307 v4 unlock indicator is on Found #21 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #21 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #21 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #20 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #20 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #19 errors of type = ERROR ch -307 v2 unlock indicator is on Found #19 errors of type = ERROR ch -301 v8 module is not in remote Found #18 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #18 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #17 errors of type = ERROR ch -304 v7 TPI selection does not check with requested setting Found #17 errors of type = ERROR ch -307 v7 unlock indicator is on Found #17 errors of type = ERROR ch -303 v7 bandwidth does not check with requested value Found #17 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #17 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #17 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #16 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #15 errors of type = ERROR ch -301 v1 module is not in remote Found #14 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #13 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 70K. Found #13 errors of type = ERROR ch -306 v2 LSB attenuator does not check with requested setting Found #12 errors of type = ERROR ch -302 v5 frequency does not check with requested value Found #12 errors of type = ERROR ch -301 vc module is not in remote Found #11 errors of type = ERROR ch -301 v9 module is not in remote Found #10 errors of type = ERROR ch -305 v2 USB attenuator does not check with requested setting Found #10 errors of type = ERROR ch -309 v1 alarm is on Found #10 errors of type = ERROR ch -301 v2 module is not in remote Found #10 errors of type = ERROR ma -4 Device ve timed-out on response. Found #9 errors of type = ERROR ch -309 v5 alarm is on Found #9 errors of type = ERROR ch -309 vc alarm is on Found #9 errors of type = ERROR ch -309 ve alarm is on Found #9 errors of type = ERROR ch -309 v3 alarm is on Found #9 errors of type = ERROR ch -309 v6 alarm is on Found #9 errors of type = ERROR ch -309 v2 alarm is on Found #8 errors of type = ERROR ch -302 v1 frequency does not check with requested value Found #8 errors of type = ERROR ch -304 v1 TPI selection does not check with requested setting Found #8 errors of type = ERROR ch -313 IF2 attenuator does not check with requested value Found #8 errors of type = ERROR ch -308 ve total power integrator overflow Found #8 errors of type = ERROR ch -302 v8 frequency does not check with requested value Found #8 errors of type = ERROR ch -307 v1 unlock indicator is on Found #8 errors of type = ERROR ch -303 v1 bandwidth does not check with requested value Found #8 errors of type = ERROR ch -312 IF1 attenuator does not check with requested value Found #8 errors of type = ERROR ch -304 v8 TPI selection does not check with requested setting Found #8 errors of type = ERROR ch -303 v8 bandwidth does not check with requested value Found #8 errors of type = ERROR ch -301 v5 module is not in remote Found #7 errors of type = ERROR ch -309 vd alarm is on Found #7 errors of type = ERROR ch -302 vc frequency does not check with requested value Found #6 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #6 errors of type = ERROR ch -309 v4 alarm is on Found #6 errors of type = ERROR ch -306 vb LSB attenuator does not check with requested setting Found #6 errors of type = ERROR ch -308 va total power integrator overflow Found #6 errors of type = ERROR ch -309 v7 alarm is on Found #6 errors of type = ERROR ch -309 v9 alarm is on Found #6 errors of type = ERROR ch -309 va alarm is on Found #6 errors of type = ERROR ch -308 vc total power integrator overflow Found #6 errors of type = ERROR ch -308 v1 total power integrator overflow Found #6 errors of type = ERROR ch -304 v5 TPI selection does not check with requested setting Found #6 errors of type = ERROR ch -309 v8 alarm is on Found #6 errors of type = ERROR ch -306 v9 LSB attenuator does not check with requested setting Found #6 errors of type = ERROR ch -309 vb alarm is on Found #6 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #6 errors of type = ERROR ch -303 v5 bandwidth does not check with requested value Found #6 errors of type = ERROR ch -304 v9 TPI selection does not check with requested setting Found #6 errors of type = ERROR ch -305 v8 USB attenuator does not check with requested setting Found #6 errors of type = ERROR ch -305 v9 USB attenuator does not check with requested setting Found #6 errors of type = ERROR ch -308 vd total power integrator overflow Found #6 errors of type = ERROR ch -302 v9 frequency does not check with requested value Found #6 errors of type = ERROR ch -306 v8 LSB attenuator does not check with requested setting Found #6 errors of type = ERROR ch -308 v3 total power integrator overflow Found #6 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #6 errors of type = ERROR ch -303 v9 bandwidth does not check with requested value Found #6 errors of type = ERROR ch -305 vb USB attenuator does not check with requested setting Found #5 errors of type = ERROR sc -10 setcl: failed too many times couldn't check formatter time Found #5 errors of type = ERROR ch -305 v4 USB attenuator does not check with requested setting Found #5 errors of type = ERROR sc -12 setcl: FS to computer time difference 0.5 seconds or greater Found #5 errors of type = ERROR sc -15 setcl: Cannot determine NTP sync state Found #5 errors of type = ERROR ch -306 v4 LSB attenuator does not check with requested setting Found #5 errors of type = ERROR ma -4 Device v6 timed-out on response. Found #4 errors of type = ERROR ch -303 v3 bandwidth does not check with requested value Found #4 errors of type = ERROR ch -301 v6 module is not in remote Found #4 errors of type = ERROR ch -302 ve frequency does not check with requested value Found #4 errors of type = ERROR ch -304 ve TPI selection does not check with requested setting Found #4 errors of type = ERROR ch -301 v4 module is not in remote Found #4 errors of type = ERROR ch -302 v3 frequency does not check with requested value Found #4 errors of type = ERROR ch -307 v3 unlock indicator is on Found #4 errors of type = ERROR ch -303 ve bandwidth does not check with requested value Found #3 errors of type = ERROR ch -301 v7 module is not in remote Found #3 errors of type = ERROR ma -4 Device v2 timed-out on response. Found #3 errors of type = ERROR ch -307 v5 unlock indicator is on Found #3 errors of type = ERROR ch -303 vd bandwidth does not check with requested value Found #3 errors of type = ERROR ch -307 ve unlock indicator is on Found #3 errors of type = ERROR ch -304 vd TPI selection does not check with requested setting Found #3 errors of type = ERROR ch -307 vd unlock indicator is on Found #3 errors of type = ERROR ch -301 v3 module is not in remote Found #3 errors of type = ERROR ch -306 v5 LSB attenuator does not check with requested setting Found #3 errors of type = ERROR ch -307 v8 unlock indicator is on Found #3 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #3 errors of type = ERROR ch -307 v9 unlock indicator is on Found #3 errors of type = ERROR ch -302 vd frequency does not check with requested value Found #3 errors of type = ERROR ch -305 v5 USB attenuator does not check with requested setting Found #2 errors of type = ERROR ch -304 va TPI selection does not check with requested setting Found #2 errors of type = ERROR ma -4 Device fm timed-out on response. Found #2 errors of type = ERROR ch -306 ve LSB attenuator does not check with requested setting Found #2 errors of type = ERROR ch -302 va frequency does not check with requested value Found #2 errors of type = ERROR ch -305 ve USB attenuator does not check with requested setting Found #2 errors of type = ERROR ch -348 Receiver LO is unlocked. Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #2 errors of type = ERROR ch -301 ve module is not in remote Found #2 errors of type = ERROR m5 -904 MARK5 return code 4: error encountered (during attempt to execute) Found #2 errors of type = ERROR ch -303 va bandwidth does not check with requested value Found #2 errors of type = ERROR ch -307 va unlock indicator is on Found #2 errors of type = ERROR sp -3 More than 12 characters in function or procedure name. Found #2 errors of type = ERROR ch -304 v3 TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -304 vc TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -304 v6 TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -307 vc unlock indicator is on Found #1 errors of type = ERROR ch -307 v6 unlock indicator is on Found #1 errors of type = ERROR m5 -900 Data transfer in progress Found #1 errors of type = ERROR m5 -900 Can't get SS version Found #1 errors of type = ERROR ch -302 v6 frequency does not check with requested value Found #1 errors of type = ERROR ch -303 vc bandwidth does not check with requested value Found #1 errors of type = ERROR ch -303 v6 bandwidth does not check with requested value Found #1 errors of type = ERROR m5 -900 Can't get device info Found #1 errors of type = ERROR m5 -900 Previous recording still active Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: etc Tsys2 values are: etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= nt1= st1= tt= set scale tsys1 [2] min max set scale tsys2 [2] min max set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100