Starting generation of Calibration File FS version = 0009.0006.0002 time_zero = 16308000 Found #271 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #244 errors of type = ERROR ch -351 Tape head 1 is not in requested position. Found #237 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #176 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #108 errors of type = ERROR ch -308 v5 total power integrator overflow Found #103 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. Found #103 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #103 errors of type = ERROR qg -305 AUX data differs from expected value on track 1. Found #103 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #44 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 65K. Found #44 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 30K. Found #34 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #33 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #32 errors of type = ERROR st -14 Antenna stuck. Found #31 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #30 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #27 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #25 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #23 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #23 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #21 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #19 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #16 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #13 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #11 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #9 errors of type = ERROR ch -308 va total power integrator overflow Found #9 errors of type = ERROR ch -308 v9 total power integrator overflow Found #6 errors of type = ERROR ch -365 IF3 switch 2 setting does not check with request. Found #5 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #4 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #4 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #4 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #3 errors of type = ERROR ch -334 Tape should be moving and it's stopped Found #3 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #2 errors of type = ERROR sp -3 More than 12 characters in function or procedure name. Found #2 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #2 errors of type = ERROR q< -301 Vacuum is not ready. Found #2 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 15. Found #1 errors of type = ERROR qg -304 Track 27 sync errors exceed threshold. Found #1 errors of type = ERROR qg -306 No tracks selected was command set-up Found #1 errors of type = ERROR qg -315 Bandwidth must be set with repro command first. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 3. Found #1 errors of type = ERROR qg -304 Track 21 sync errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 25 sync errors exceed threshold. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 5. Found #1 errors of type = ERROR qg -304 Track 17 sync errors exceed threshold. Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 43.89 max= 45.72 RX2 min= 38.88 max= 40.59 RX3 min= 0.147 max= 0.150 Plotting 3 Tsys channels: 01 05 09 Tsys1 values are: etc Tsys2 values are: etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= nt1= st1= tt= set scale tsys1 [2] min max set scale tsys2 [2] min max set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100