Starting generation of Calibration File FS version = 0009.0006.0002 time_zero = 15703200 Found #267 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #240 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #235 errors of type = ERROR ch -351 Tape head 1 is not in requested position. Found #182 errors of type = ERROR ch -308 va total power integrator overflow Found #148 errors of type = ERROR ch -342 Tape is not in ready state (vacuum not ready) Found #109 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #109 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #108 errors of type = ERROR qg -305 AUX data differs from expected value on track 1. Found #108 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. Found #76 errors of type = ERROR q< -301 Vacuum is not ready. Found #40 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #38 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #38 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #33 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #33 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #32 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #31 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #30 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #28 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #27 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #26 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #25 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #24 errors of type = ERROR qg -305 AUX data differs from expected value on track 5. Found #24 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #23 errors of type = ERROR qg -305 AUX data differs from expected value on track 27. Found #23 errors of type = ERROR qg -305 AUX data differs from expected value on track 11. Found #23 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #23 errors of type = ERROR qg -305 AUX data differs from expected value on track 3. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 17. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 7. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #21 errors of type = ERROR qg -305 AUX data differs from expected value on track 15. Found #21 errors of type = ERROR qg -305 AUX data differs from expected value on track 9. Found #21 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #21 errors of type = ERROR qg -305 AUX data differs from expected value on track 19. Found #8 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #6 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #6 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #6 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #4 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #4 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 30K. Found #4 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 65K. Found #3 errors of type = ERROR ch -365 IF3 switch 2 setting does not check with request. Found #3 errors of type = ERROR qg -304 Track 5 sync errors exceed threshold. Found #2 errors of type = ERROR ch -334 Tape should be moving and it's stopped Found #2 errors of type = ERROR qg -304 Track 3 sync errors exceed threshold. Found #2 errors of type = ERROR sp -13 This command not supported for your equipment check equip.ctl. Found #2 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #2 errors of type = ERROR qa -201 Tape number must be 8 charaters. Found #1 errors of type = ERROR qg -304 Track 21 sync errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 25 sync errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 27 sync errors exceed threshold. Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 44.01 max= 45.97 RX2 min= 38.76 max= 40.47 RX3 min= 0.146 max= 0.150 Plotting 3 Tsys channels: 01 05 09 Tsys1 values are: etc Tsys2 values are: etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= nt1= st1= tt= set scale tsys1 [2] min max set scale tsys2 [2] min max set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100