Starting generation of Calibration File FS version = 0009.0006.0002 time_zero = 14493600 Found #270 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #128 errors of type = ERROR ib -4 GPIB Device time-out on response ca Found #100 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #100 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #99 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. Found #98 errors of type = ERROR qg -305 AUX data differs from expected value on track 1. Found #92 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #92 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #90 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #88 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #81 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #76 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #73 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #73 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #71 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #61 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #43 errors of type = ERROR st -14 Antenna stuck. Found #42 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #40 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #25 errors of type = ERROR qg -304 Track 25 sync errors exceed threshold. Found #23 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #19 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #17 errors of type = ERROR qg -304 Track 27 sync errors exceed threshold. Found #16 errors of type = ERROR qg -304 Track 23 sync errors exceed threshold. Found #16 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #16 errors of type = ERROR qg -304 Track 17 sync errors exceed threshold. Found #9 errors of type = ERROR ch -365 IF3 switch 2 setting does not check with request. Found #8 errors of type = ERROR qg -305 AUX data differs from expected value on track 17. Found #8 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #7 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 65K. Found #7 errors of type = ERROR ch -308 v5 total power integrator overflow Found #7 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 30K. Found #6 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 5. Found #4 errors of type = ERROR ch -303 v3 bandwidth does not check with requested value Found #4 errors of type = ERROR ch -306 v3 LSB attenuator does not check with requested setting Found #4 errors of type = ERROR ch -364 IF3 switch 1 setting does not check with request. Found #4 errors of type = ERROR ch -304 vb TPI selection does not check with requested setting Found #4 errors of type = ERROR ch -306 vb LSB attenuator does not check with requested setting Found #4 errors of type = ERROR ch -306 vc LSB attenuator does not check with requested setting Found #4 errors of type = ERROR ch -304 v3 TPI selection does not check with requested setting Found #4 errors of type = ERROR ch -305 v3 USB attenuator does not check with requested setting Found #4 errors of type = ERROR ch -303 vb bandwidth does not check with requested value Found #4 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #4 errors of type = ERROR ch -302 v3 frequency does not check with requested value Found #4 errors of type = ERROR ch -304 vc TPI selection does not check with requested setting Found #3 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #3 errors of type = ERROR qg -305 AUX data differs from expected value on track 11. Found #3 errors of type = ERROR qg -304 Track 21 sync errors exceed threshold. Found #3 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #3 errors of type = ERROR qg -305 AUX data differs from expected value on track 7. Found #2 errors of type = ERROR ch -309 v3 alarm is on Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 19. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #2 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 3. Found #2 errors of type = ERROR ch -309 v6 alarm is on Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 9. Found #2 errors of type = ERROR ch -309 vb alarm is on Found #2 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #1 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #1 errors of type = ERROR ch -4 Device v8 timed-out on response from MATCN Found #1 errors of type = ERROR qg -304 Track 15 sync errors exceed threshold. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 27. Found #1 errors of type = ERROR ch -301 vd module is not in remote Found #1 errors of type = ERROR ch -308 va total power integrator overflow Found #1 errors of type = ERROR ch -4 Device va timed-out on response from MATCN Found #1 errors of type = ERROR ch -4 Device vb timed-out on response from MATCN Found #1 errors of type = ERROR ch -4 Device vc timed-out on response from MATCN Found #1 errors of type = ERROR qg -304 Track 3 sync errors exceed threshold. Found #1 errors of type = ERROR ch -4 Device v9 timed-out on response from MATCN Found #1 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #1 errors of type = ERROR ch -4 Device v7 timed-out on response from MATCN Found #1 errors of type = ERROR qg -304 Track 13 sync errors exceed threshold. Found #1 errors of type = ERROR ch -348 Receiver LO is unlocked. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 15. Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 44.13 max= 45.72 RX2 min= 38.52 max= 40.35 RX3 min= 0.145 max= 0.148 Plotting 3 Tsys channels: 01 05 09 Tsys1 values are: etc Tsys2 values are: etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= nt1= st1= tt= set scale tsys1 [2] min max set scale tsys2 [2] min max set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100