Starting generation of Calibration File FS version = 0009.0006.0002 time_zero = 10864800 Found #381 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #380 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #375 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #116 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #107 errors of type = ERROR qg -305 AUX data differs from expected value on track 1. Found #107 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. Found #107 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #107 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #81 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #79 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #75 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #68 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #67 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #55 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #47 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #46 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #41 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #31 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #30 errors of type = ERROR st -14 Antenna stuck. Found #20 errors of type = ERROR ch -308 va total power integrator overflow Found #15 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #15 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #10 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #9 errors of type = ERROR ch -351 Tape head 1 is not in requested position. Found #4 errors of type = ERROR qg -304 Track 3 sync errors exceed threshold. Found #4 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #4 errors of type = ERROR ch -308 v9 total power integrator overflow Found #3 errors of type = ERROR qg -305 AUX data differs from expected value on track 11. Found #3 errors of type = ERROR qg -305 AUX data differs from expected value on track 5. Found #3 errors of type = ERROR qg -305 AUX data differs from expected value on track 3. Found #2 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #2 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #1 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #1 errors of type = ERROR qg -304 Track 11 sync errors exceed threshold. Found #1 errors of type = ERROR ch -303 v9 bandwidth does not check with requested value Found #1 errors of type = ERROR ch -309 v9 alarm is on Found #1 errors of type = ERROR ch -306 v9 LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -305 v9 USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -304 v9 TPI selection does not check with requested setting Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 17. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 7. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 19. Found #1 errors of type = ERROR sp -3 More than 12 characters in function or procedure name. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 9. Found #1 errors of type = ERROR ch -302 v9 frequency does not check with requested value Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 27. Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 43.40 max= 2005.125.18:10:40.05 RX2 min= 37.91 max= 41.69 RX3 min= 0.143 max= 0.147 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r4172ft.log.tsy1.ntup nt1= 7 st1= 1u tt= 1 set scale tsys1 [2] min max 68.7 238.1 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 300 ymax 305 in match_chan ft1= r4172ft.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 68.7 238.1 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 144.1 ymax 305 in match_chan ft1= r4172ft.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 68.7 238.1 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 28.4 ymax 305