Starting generation of Calibration File FS version = 0009.0006.0002 time_zero = 9655200 Found #354 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #338 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #208 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #107 errors of type = ERROR qg -305 AUX data differs from expected value on track 1. Found #107 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #107 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #99 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. Found #99 errors of type = ERROR ch -308 v1 total power integrator overflow Found #93 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #87 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #86 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #83 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #79 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #76 errors of type = ERROR st -14 Antenna stuck. Found #68 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #68 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #62 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #57 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #54 errors of type = ERROR qg -304 Track 23 sync errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #44 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #42 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #30 errors of type = ERROR ch -351 Tape head 1 is not in requested position. Found #29 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #16 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #16 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #14 errors of type = ERROR ch -365 IF3 switch 2 setting does not check with request. Found #11 errors of type = ERROR qg -304 Track 3 sync errors exceed threshold. Found #11 errors of type = ERROR qg -305 AUX data differs from expected value on track 9. Found #9 errors of type = ERROR ch -301 v1 module is not in remote Found #9 errors of type = ERROR qg -305 AUX data differs from expected value on track 3. Found #9 errors of type = ERROR qg -305 AUX data differs from expected value on track 17. Found #8 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 5. Found #7 errors of type = ERROR qg -304 Track 19 sync errors exceed threshold. Found #7 errors of type = ERROR qg -304 Track 25 sync errors exceed threshold. Found #6 errors of type = ERROR qg -305 AUX data differs from expected value on track 27. Found #6 errors of type = ERROR qg -305 AUX data differs from expected value on track 11. Found #5 errors of type = ERROR qg -304 Track 5 sync errors exceed threshold. Found #5 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 15. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 7. Found #5 errors of type = ERROR qg -304 Track 15 sync errors exceed threshold. Found #5 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #4 errors of type = ERROR ch -309 v3 alarm is on Found #4 errors of type = ERROR ch -309 v6 alarm is on Found #4 errors of type = ERROR qg -304 Track 17 sync errors exceed threshold. Found #4 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #4 errors of type = ERROR ch -309 vb alarm is on Found #4 errors of type = ERROR qg -305 AUX data differs from expected value on track 19. Found #4 errors of type = ERROR qg -304 Track 27 sync errors exceed threshold. Found #3 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #3 errors of type = ERROR qg -304 Track 7 sync errors exceed threshold. Found #3 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 30K. Found #3 errors of type = ERROR qg -304 Track 13 sync errors exceed threshold. Found #3 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 65K. Found #2 errors of type = ERROR ch -334 Tape should be moving and it's stopped Found #1 errors of type = ERROR qg -304 Track 11 sync errors exceed threshold. Found #1 errors of type = ERROR ch -309 v1 alarm is on Found #1 errors of type = ERROR qg -304 Track 9 sync errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #1 errors of type = ERROR qa -202 Check label doesn't match. Check it and try again. Found #1 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 45.23 max= 2005.111.18:09:38.04 RX2 min= 39.98 max= 43.65 RX3 min= 0.146 max= 0.148 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r4170ft.log.tsy1.ntup nt1= 7 st1= 1u tt= 1 set scale tsys1 [2] min max 64.5 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305 in match_chan ft1= r4170ft.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 64.5 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 134.5 ymax 305 in match_chan ft1= r4170ft.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 64.5 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 16.6 ymax 305