Starting generation of Calibration File FS version = 0009.0007.0005 time_zero = 26323200 Found #163 errors of type = ERROR 4f -501 Formatter was failing the synch test. Found #10 errors of type = ERROR un 115 Operation now in progress Found #10 errors of type = ERROR m5 -23 mk5cn: socket open error from getsockopt() Found #4 errors of type = ERROR qk -211 Tsys value for device ic overflowed or was less than zero. Found #3 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #3 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #2 errors of type = ERROR m5 -900 Check formatter serial number even Found #2 errors of type = ERROR st -1 Antenna got the wrong angles Found #2 errors of type = ERROR ch -348 Receiver LO is unlocked. Found #2 errors of type = ERROR qk -211 Tsys value for device ib overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 2u overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 3u overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 4u overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 5u overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 6u overflowed or was less than zero. Found #1 errors of type = ERROR mc -2 Interface b3 responded but did not ACKnowledge. Found #1 errors of type = ERROR qk -211 Tsys value for device 8u overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 8l overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 9u overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device cu overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device eu overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device du overflowed or was less than zero. Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR qk -211 Tsys value for device au overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device bu overflowed or was less than zero. Found #1 errors of type = ERROR st -3 Commanding angles okay now. Found #1 errors of type = ERROR qk -211 Tsys value for device 7u overflowed or was less than zero. Found these BBCs: bbc02 bbc06 bbc11 NBBC: 3 Found these RX parameters: 00(front) 02(lo) 03(dcal) RX1 min= 16.30 max= 2005.304.16:38:02.89 RX2 min= 27.04 max= 33.39 RX3 min= 26.43 max= 32.90 Plotting 3 Tsys channels: 02 06 11 Tsys values are: -1 1 2 etc NTSYS: 3 in match_chan ft1= r1196gc.log.tsy1.ntup nt1= 9 st1= 2u tt= 1 set scale tsys1 [2] min max 47.1 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 42.1 ymax 305 in match_chan ft1= r1196gc.log.tsy1.ntup nt1= 20 st1= 6u tt= 1 set scale tsys1 [2] min max 47.1 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 32.4 ymax 305 in match_chan ft1= r1196gc.log.tsy1.ntup nt1= 14 st1= bu tt= 1 set scale tsys1 [2] min max 47.1 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 55.5 ymax 305