Starting generation of Calibration File FS version = 0009.0007.0007 time_zero = 21571200 Found #751 errors of type = ERROR ma -4 Device rx timed-out on response. Found #71 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #70 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #68 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #64 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #63 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #62 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #61 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #60 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #59 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #59 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #59 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #58 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #55 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #53 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #53 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #50 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #45 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #34 errors of type = ERROR ch -4 Device rx timed-out on response from MATCN Found #24 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #9 errors of type = ERROR ch -371 IF3 alarm is on Found #3 errors of type = ERROR ch -308 vb total power integrator overflow Found #3 errors of type = ERROR ch -361 IF3 module is not in remote Found #2 errors of type = ERROR ch -368 IF3 frequency does not check with equip.ctl value. Found #2 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 30K. Found #2 errors of type = ERROR ch -308 vc total power integrator overflow Found #1 errors of type = ERROR m5 -900 Must be off or on Found #1 errors of type = ERROR m5 -908 MARK5 return code 8: parameter error Found #1 errors of type = ERROR ch -309 v6 alarm is on Found #1 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 70K. Found #1 errors of type = ERROR ch -365 IF3 switch 2 setting does not check with request. Found #1 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #1 errors of type = ERROR ch -364 IF3 switch 1 setting does not check with request. Found #1 errors of type = ERROR ch -362 IF3 attenuator does not check with requested value. Found #1 errors of type = ERROR ch -308 vd total power integrator overflow Found #1 errors of type = ERROR ch -4 Device i3 timed-out on response from MATCN Found #1 errors of type = ERROR ch -369 IF3 lo is unlocked. Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: etc Tsys2 values are: etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= nt1= st1= tt= set scale tsys1 [2] min max set scale tsys2 [2] min max set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100