Starting generation of Calibration File FS version = 0009.0007.0007 time_zero = 21571200 Found #75 errors of type = ERROR ch -308 vc total power integrator overflow Found #28 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #25 errors of type = ERROR ch -308 vd total power integrator overflow Found #20 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #16 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #8 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #4 errors of type = ERROR ib -4 GPIB Device time-out on response gt Found #4 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #1 errors of type = ERROR m5 -900 Check formatter serial number even Found #1 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #1 errors of type = ERROR ch -348 Receiver LO is unlocked. Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these RX parameters: 00(FRONT) 01(REAR) 02(LO) RX1 min= 14.95 max= 30.70 RX2 min= 20.57 max= 34.86 RX3 min= 20.45 max= 34.98 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: etc Tsys2 values are: etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= nt1= st1= tt= set scale tsys1 [2] min max set scale tsys2 [2] min max set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100