Starting generation of Calibration File FS version = 0009.0007.0007 time_zero = 18460800 Found #3071 errors of type = ERROR ma -4 Device rx timed-out on response. Found #41 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #38 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #37 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #34 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #33 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #32 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #32 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #32 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #31 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #31 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #31 errors of type = ERROR ch -301 v2 module is not in remote Found #31 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #30 errors of type = ERROR ch -301 ve module is not in remote Found #30 errors of type = ERROR ch -301 v1 module is not in remote Found #30 errors of type = ERROR ch -301 vc module is not in remote Found #30 errors of type = ERROR ch -301 v5 module is not in remote Found #30 errors of type = ERROR ch -301 va module is not in remote Found #30 errors of type = ERROR ch -301 v6 module is not in remote Found #30 errors of type = ERROR ch -301 v4 module is not in remote Found #30 errors of type = ERROR ch -301 v7 module is not in remote Found #30 errors of type = ERROR ch -301 v9 module is not in remote Found #30 errors of type = ERROR ch -301 vd module is not in remote Found #30 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #30 errors of type = ERROR ch -301 v8 module is not in remote Found #30 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #30 errors of type = ERROR ch -301 v3 module is not in remote Found #30 errors of type = ERROR ch -301 vb module is not in remote Found #29 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #29 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #27 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #27 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #24 errors of type = ERROR ch -311 IF distributor is not in remote Found #24 errors of type = ERROR ch -361 IF3 module is not in remote Found #24 errors of type = ERROR ma -8(fm) Found #6 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #4 errors of type = ERROR sc -12 setcl: FS to computer time difference 0.5 seconds or greater Found #4 errors of type = ERROR ch -305 v1 USB attenuator does not check with requested setting Found #4 errors of type = ERROR ch -303 v1 bandwidth does not check with requested value Found #4 errors of type = ERROR sc -10 setcl: failed too many times couldn't check formatter time Found #4 errors of type = ERROR ch -309 v1 alarm is on Found #4 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #4 errors of type = ERROR sc -15 setcl: Cannot determine NTP sync state Found #4 errors of type = ERROR ch -302 v1 frequency does not check with requested value Found #4 errors of type = ERROR ch -306 v1 LSB attenuator does not check with requested setting Found #2 errors of type = ERROR m5 -900 Check formatter serial number even Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR ch -4 Device rx timed-out on response from MATCN Found #1 errors of type = ERROR ch -309 v6 alarm is on Found #1 errors of type = ERROR ch -307 v1 unlock indicator is on Found #1 errors of type = ERROR sp -3 More than 12 characters in function or procedure name. Found #1 errors of type = ERROR sc -5 setcl: formatter time garbled Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: etc Tsys2 values are: etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= nt1= st1= tt= set scale tsys1 [2] min max set scale tsys2 [2] min max set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100